An ultrasonic sensor consists of a sensor portion that transmits and receives ultrasonic waves and a preamplifier that amplifies them. The ultrasonic sensor outputs the ultrasonic waves and sends the received signals to the clearance warning ECU assembly.
Remove the rear center ultrasonic sensor (LH) (See page Audio / Visual / Telematics>PARK ASSIST / MONITORING>ULTRASONIC SENSOR(for Rear Side)>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (BI) - 5 (EI) | Always | 10 kΩ or higher |
| 1 (BI) - 2 (BO) | Always | 10 kΩ or higher |
| 3 (SI) - 4 (SO) | Always | Below 1 Ω |
| 5 (EI) - 6 (EO) | Always | Below 1 Ω |
| *a | Component without harness connected
(Rear Center Ultrasonic Sensor (LH)) |
OK
NG
(See pageAudio / Visual / Telematics>PARK ASSIST / MONITORING>ULTRASONIC SENSOR(for Rear Side)>REMOVAL)
Disconnect the R11 and R12 rear center ultrasonic sensor connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| R11-1 (BI) - R12-2 (BO) | Always | Below 1 Ω |
| R11-3 (SI) - R12-4 (SO) | Always | Below 1 Ω |
| R11-5 (EI) - R12-6 (EO) | Always | Below 1 Ω |
| R11-1 (BI) - Body ground | Always | 10 kΩ or higher |
| R11-3 (SI) - Body ground | Always | 10 kΩ or higher |
| R11-5 (EI) - Body ground | Always | 10 kΩ or higher |
OK
NG