2011-2016 FJ Cruiser · Service Manual ENGINE

P0037 Oxygen Sensor Heater Control Circuit Low (Bank 1 Sensor 2)

Diagnostic trouble codes · Vehicles built Jul 2007 – Nov 2007

Also covers:

Versions by build date: Jul 2007 – Nov 2007 Dec 2007 – Jul 2009 Aug 2009 – Jul 2014 from Aug 2014

DESCRIPTION

Refer to DTC P0136 (Click here).

HINT:
  1. When any of these DTCs are set, the ECM enters fail-safe mode. The ECM turns off the Heated Oxygen (HO2) Sensor heater in fail-safe mode. Fail-safe mode continues until the engine switch is turned off.
  2. Sensor 2 refers to the sensor mounted behind the Three-Way Catalytic Converter (TWC) and located far from the engine assembly.

  3. The ECM provides a pulse width modulated control circuit to adjust the current through the heater. The HO2 sensor heater circuit uses a relay on the +B side of the circuit.

    A103832E33
DTC No.
DTC Detection Conditions
Trouble Areas
P0037
P0057
Heated Oxygen (HO2) sensor heater current less than 0.3 A (1 trip detection logic)
  1. Open in HO2 sensor heater circuit
  2. HO2 sensor heater
  3. EFI relay
  4. ECM
P0038
P0058
Heated Oxygen (HO2) sensor heater current more than 2 A (1 trip detection logic)
  1. Short in HO2 sensor heater circuit
  2. HO2 sensor heater
  3. EFI relay
  4. ECM

HINT:
  1. Bank 1 refers to the bank that includes cylinder No. 1.
  2. Bank 2 refers to the bank that does not include cylinder No. 1.
  3. Sensor 1 refers to the sensor closest to the engine assembly.
  4. Sensor 2 refers to the sensor farthest away from the engine assembly.


MONITOR DESCRIPTION

The sensing position of the Heated Oxygen (HO2) sensor has a zirconia element which is used to detect the oxygen concentration in the exhaust gas. If the zirconia element is at the appropriate temperature, and the difference between the oxygen concentrations surrounding the inside and outside surfaces of the sensor is large, the zirconia element generates voltage signals. In order to increase the oxygen concentration detecting capacity of the zirconia element, the ECM supplements the heat from the exhaust with heat from a heating element inside the sensor.
  1. Heated oxygen sensor heater range check (P0037, P0038, P0057 and P0058):
    1. The ECM monitors the current applied to the O2 sensor heater to check the heater for malfunctions. If the current is below the threshold value, the ECM will determine that there is an open circuit in the heater. If the current is above the threshold value, the ECM will determine that there is a short circuit in the heater.
      1. Example:
        1. The ECM sets DTC P0038 or P0058 when the current in the HO2 sensor heater is more than 2 A. Conversely, when the heater current is less than 0.3 A, DTC P0037 or P0057 is set.

WIRING DIAGRAM

Refer to DTC P0136 (Click here).

INSPECTION PROCEDURE

HINT:
Read freeze frame data using an intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.


1. INSPECT HEATED OXYGEN SENSOR (HEATER RESISTANCE)

  1. A133485E01
    Disconnect the B36*1 or B34*2 Heated Oxygen (HO2) sensor connectors.

    HINT:
    1. *1: Bank 1 Sensor 2
    2. *2: Bank 2 Sensor 2

  1. Measure the resistance between the terminals of the HO2 sensor connector.

    Standard Resistance (Bank 1 Sensor 2):
    Tester Connections
    Specified Conditions
    HT1B (1) - +B (2)
    11 to 16 Ω at 20°C (68°F)
    HT1B (1) - E2 (4)
    10 kΩ or higher

    Standard Resistance (Bank 2 Sensor 2):
    Tester Connections
    Specified Conditions
    HT2B (1) - +B (2)
    11 to 16 Ω at 20°C (68°F)
    HT2B (1) - E2 (4)
    10 kΩ or higher

  1. Reconnect the HO2 sensor connector.



NG
REPLACE HEATED OXYGEN SENSOR (Click here)
OK


2. INSPECT EFI RELAY
A133434E03
  1. Remove the EFI relay from the engine room relay block.

  1. Check the EFI relay resistance.

    Standard Resistance:
    Tester Connections
    Specified Conditions
    3 - 5
    10 kΩ or higher
    Below 1 Ω
    (when battery voltage applied to terminals 1 and 2)

  1. Reinstall the EFI relay.



NG
REPLACE EFI RELAY
OK


3. INSPECT ECM (HT1B OR HT2B VOLTAGE)

  1. A115970E21
    Turn the ignition switch ON.

  1. Measure the voltage between the terminals of the ECM connectors.

    Standard Resistance:
    Tester Connections
    Specified Conditions
    HT1B (B1-1) - E1 (B3-1)
    11 to 14 V
    HT2B (B2-5) - E1 (B3-1)

HINT:
  1. The HT1B means the heated oxygen sensor bank 1 sensor 2.
  2. The HT2B means the heated oxygen sensor bank 2 sensor 2.



OK
REPLACE ECM (Click here)
NG


4. CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - EFI NO. 2 FUSE)

  1. A133484E03
    Check the harness and connector between the HO2 sensor and EFI No. 2 fuse.
    1. Disconnect the B36*1 or B34*2 HO2 sensor connector.

      HINT:
      1. *1: Bank 1 Sensor 2
      2. *2: Bank 2 Sensor 2

    2. Remove the EFI No. 2 fuse from the engine room relay block.

    3. Check the resistance.

      Standard Resistance:
      Tester Connections
      Specified Conditions
      +B (B36-2) - EFI No. 2 fuse (2)
      Below 1 Ω
      +B (B34-2) - EFI No. 2 fuse (2)

      Standard Resistance:
      Tester Connections
      Specified Conditions
      +B (B36-2) or EFI No. 2 fuse (2) - Body ground
      10 kΩ or higher
      +B (B34-2) or EFI No. 2 fuse (2) - Body ground

    4. Reconnect the HO2 sensor connector.

    5. Reconnect the EFI No. 2 fuse.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


5. CHECK HARNESS AND CONNECTOR (HEATED OXYGEN SENSOR - ECM)

  1. A133482E01
    Check the harness and connector between the ECM and HO2 sensor.
    1. Disconnect the B36*1 or B34*2 HO2 sensor connector.

      HINT:
      1. *1: Bank 1 Sensor 2
      2. *2: Bank 2 Sensor 2

    2. Remove the B1 and B2 ECM connector.

    3. Check the resistance.

      Standard Resistance:
      Tester Connections
      Specified Conditions
      HT1B (B36-1) - HT1B (B1-1)
      Below 1 Ω
      HT2B (B34-1) - HT2B (B2-5)

      Standard Resistance:
      Tester Connections
      Specified Conditions
      HT1B (B36-1) or HT1B (B1-1) - Body ground
      10 kΩ or higher
      HT2B (B34-1) or HT2B (B2-5) - Body ground

    4. Reconnect the HO2 sensor connector.

    5. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)