2011-2016 FJ Cruiser · Service Manual ENGINE

P0116 Engine Coolant Temperature Circuit Range / Performance Problem

Diagnostic trouble codes · Vehicles built Nov 2012 – Jul 2014

Versions by build date: Jul 2007 – Nov 2007 Dec 2007 – Jul 2009 Aug 2009 – Oct 2010 Nov 2010 – Jul 2012 Aug 2012 – Oct 2012 Nov 2012 – Jul 2014 from Aug 2014

DESCRIPTION

Refer to DTC P0115 (Click here).
DTC No.
DTC Detection Condition
Trouble Area
P0116
For Euro-OBD LHD Models:
When either of following conditions met (2 trip detection logic):
  1. During engine warming up after cold engine start, change in Engine Coolant Temperature (ECT) sensor output below threshold
  2. In duration between warmed engine stopped and next cold engine start, change in ECT sensor output below threshold
  1. Water inlet with thermostat
  2. ECT sensor
P0116
Except Euro-OBD LHD Models:
Case 1:
Engine Coolant Temperature (ECT) between 35°C and 60°C (95°F and 140°F) when engine started, and conditions (a) and (b) met (2 trip detection logic)
(a) Vehicle driven at varying speeds (accelerated and decelerated)
(b) ECT remains within 3°C (5.4°F) of initial ECT
Case 2:
ECT more than 60°C (140°F) when engine started, and conditions (a) and (b) met (6 trip detection logic)
(a) Vehicle driven at varying speeds (accelerated and decelerated)
(b) ECT measurements remain within 1°C (1.8°F) of initial ECT on 6 successive occasions
  1. Water inlet with thermostat
  2. ECT sensor

MONITOR DESCRIPTION

  1. Engine coolant temperature (ECT) sensor cold start monitor (for Euro-OBD LHD models)
    When a cold engine start is performed and then the engine is warmed up, if the ECT sensor value does not change, it is determined that a malfunction has occurred. If this is detected in 2 consecutive driving cycles, the MIL is illuminated and a DTC is stored.
  1. ECT sensor soak monitor (for Euro-OBD LHD models)
    If the ECT sensor value does not change after the warmed up engine is stopped and then the next cold engine start is performed, it is determined that a malfunction has occurred. If this is detected in 2 consecutive driving cycles, the MIL is illuminated and a DTC is stored.
  1. ECT sensor high side stuck monitor (Except Euro-OBD LHD models)
    The ECM monitors the sensor voltage and uses this value to calculate the ECT. If the sensor voltage output deviates from the normal operating range, the ECM interprets this deviation as a malfunction in the ECT sensor and stores the DTC.
  1. Examples:
    1. Upon starting the engine, the ECT is between 35°C and 60°C (95°F and 140°F). If after driving for 250 seconds, the ECT remains within 3°C (5.4°F) of the starting temperature, the DTC is stored (2 trip detection logic).
    2. Upon starting the engine, the ECT is over 60°C (140°F). If after driving at varying speeds (accelerating and decelerating) for a specified period of time, the ECT remains within 1°C (1.8°F) of the starting temperature, the DTC is stored (6 trip detection logic).

INSPECTION PROCEDURE

HINT:
  1. If any of DTCs P0115, P0117 or P0118 are stored simultaneously with DTC P0116, the ECT sensor may have an open or a short circuit. Troubleshoot those DTCs first.
  2. Read freeze frame data using the intelligent tester. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, if the air-fuel ratio was lean or rich, and other data from the time the malfunction occurred.


1. CHECK ANY OTHER DTCS OUTPUT (IN ADDITION TO DTC P0116)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch to ON.

  1. Turn the tester on.

  1. Enter the following menus: Powertrain / Engine and ECT / DTC.

  1. Read the DTC.

    Result 
    Result
    Proceed to
    P0116 is output
    A
    P0116 and other DTCs are output
    B



B
GO TO DTC CHART (Click here)
A


2. INSPECT WATER INLET WITH THERMOSTAT
  1. Remove the water inlet with thermostat (Click here).

  1. Measure the valve opening temperature of the thermostat.

    Standard opening temperature:
    80 to 84°C (176 to 183°F)

    HINT:
    In addition to the above check, confirm that the valve is completely closed when the temperature is below the standard.



NG
REPLACE WATER INLET WITH THERMOSTAT (Click here)
OK

REPLACE ENGINE COOLANT TEMPERATURE SENSOR (Click here)


← P0116 Engine Coolant Temperature Circuit Range / Performance Problem (Aug 2012 – Oct 2012)P0116 Engine Coolant Temperature Circuit Range / Performance Problem (from Aug 2014) →