INSPECTION
Inspection · Vehicles built from Jul 2007
| INSPECT NO. 1 COOLER THERMISTOR |
![]() ![]() |
Measure the resistance.
- Standard resistance:
Tester Connection
Condition
Specified Condition
1 - 2
-10°C (14°F)
7.30 to 9.10 kΩ
1 - 2
-5°C (23°F)
5.65 to 6.95 kΩ
1 - 2
0°C (32°F)
4.40 to 5.35 kΩ
1 - 2
5°C (41°F)
3.40 to 4.15 kΩ
1 - 2
10°C (50°F)
2.70 to 3.25 kΩ
1 - 2
15°C (59°F)
2.14 to 2.58 kΩ
1 - 2
20°C (68°F)
1.71 to 2.05 kΩ
1 - 2
25°C (77°F)
1.38 to 1.64 kΩ
1 - 2
30°C (86°F)
1.11 to 1.32 kΩ
- NOTICE:
- Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
- When measuring the resistance, the temperature of the sensor and the cooler thermistor must be the same.
- Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
- If the operation is not as specified, replace the cooler thermistor.
| INSPECT MODE CONTROL SERVO MOTOR |
![]() ![]() |
Inspect the servo motor operation.
Connect the positive (+) lead from the battery to terminal 4 (DEF) and negative (-) lead to terminal 5 (FACE), then check that the lever turns to the DEF position smoothly.
- Standard:
- The motor operates smoothly.
Connect the positive (+) lead from the battery to terminal 5 (FACE) and negative (-) lead to terminal 4 (DEF), then check that the lever turns to the FACE position smoothly.
- Standard:
- The motor operates smoothly.
Check the servo motor resistance.
Using an ohmmeter, measure the resistance and check the results in accordance with the values in the table below.
- Standard resistance:
Tester Connection
Servo Motor Position
Specified Condition
1 (SG) - 2 (S5)
Always
4.2 to 7.8 kΩ
1 (SG) - 3 (TPM)
DEF Position
3.4 to 6.2 kΩ
1 (SG) - 3 (TPM)
FACE Position
0.8 to 1.6 kΩ
| REMOVE AIR MIX CONTROL SERVO MOTOR |
![]() ![]() |
Inspect the servo motor operation.
Connect the positive (+) lead from the battery to terminal 4 (MH) and negative (-) lead to terminal 5 (MC), then check that the lever turns to the MAX HOT position smoothly.
- Standard:
- The motor operates smoothly.
Connect the positive (+) lead from the battery to terminal 5 (MC) and negative (-) lead to terminal 4 (MH), then check that the lever turns to the MAX COOL position smoothly.
- Standard:
- The motor operates smoothly.
Check the servo motor resistance.
Using an ohmmeter, measure the resistance and check the results in accordance with the values in the table below.
- Standard resistance:
Tester Connection
Servo Motor Position
Specified Condition
1 (SG) - 2 (S5)
Always
4.2 to 7.8 kΩ
1 (SG) - 3 (TP)
MAX HOT Position
3.4 to 6.2 kΩ
1 (SG) - 3 (TP)
MAX COOL Position
0.8 to 1.6 kΩ