2011-2016 FJ Cruiser · Service Manual BODY

Driver Side Power Window does not Operate with Power Window Master Switch

Circuit diagnosis · Vehicles built Jul 2007 – Oct 2010

Versions by build date: Jul 2007 – Oct 2010 Nov 2010 – Jul 2011 from Aug 2011

DESCRIPTION

If the manual UP / DOWN and AUTO DOWN functions do not operate, a malfunction may be present in the power window regulator master switch, power window regulator motor or wire harness.

WIRING DIAGRAM

B173366E01

INSPECTION PROCEDURE


1. CHECK HARNESS AND CONNECTOR (SWITCH INPUT POWER SUPPLY)

  1. B173367E01
    Disconnect the H5 power window regulator master switch assembly connector.

  1. Turn the ignition switch ON.

  1. Measure the voltage of the wire harness side connector.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    H5-9 (B) - H5-1 (E)
    Ignition switch ON
    11 to 14 V

  1. Reconnect the power window regulator master switch assembly connector.



NG
CHECK AND REPLACE POWER SOURCE AND WIRE HARNESS
OK


2. INSPECT POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY

  1. B112772E04
    Remove the power window regulator master switch assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Window Lock Switch Condition
    Power Window Switch Condition
    Tester Connection
    Specified Condition
    Always
    (ON / OFF)
    UP
    1 (E) - 4 (D)
    3 (U) - 9 (B)
    Below 1 Ω
    Always
    (ON / OFF)
    OFF
    1 (E) - 3 (U)
    1 (E) - 4 (D)
    Below 1 Ω
    Always
    (ON / OFF)
    DOWN
    1 (E) - 3 (U)
    4 (D) - 9 (B)
    Below 1 Ω
    Always
    (ON / OFF)
    AUTO DOWN
    1 (E) - 3 (U)
    4 (D) - 9 (B)
    Below 1 Ω

  1. Reinstall the master switch.



NG
REPLACE POWER WINDOW REGULATOR MASTER SWITCH ASSEMBLY (Click here)
OK


3. CHECK HARNESS AND CONNECTOR (POWER WINDOW REGULATOR MASTER SWITCH - MOTOR)

  1. B137148E02
    Disconnect the H5 power window regulator master switch assembly connector.

  1. Disconnect the H3 power window regulator motor assembly LH connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Specified Condition
    H5-4 (D) - H3-1 (D)
    Below 1 Ω
    H5-3 (U) - H3-2 (U)
    Below 1 Ω
    H5-4 (D) or H3-1 (D) - Body ground
    10 kΩ or higher
    H5-3 (U) or H3-2 (U) - Body ground
    10 kΩ or higher

  1. Reconnect the motor connector.

  1. Reconnect the master switch connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE POWER WINDOW REGULATOR MOTOR ASSEMBLY LH (Click here)


← Remote Up / Down Function does not Operate (from Aug 2011)Driver Side Power Window does not Operate with Power Window Master Switch (Nov 2010 – Jul 2011) →