P0973 Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1)
Diagnostic trouble codes · Vehicles built Jul 2007 – Jul 2009
Also covers:
- P0974 Shift Solenoid "A" Control Circuit High (Shift Solenoid Valve S1)
Versions by build date: Jul 2007 – Jul 2009 from Aug 2009
DESCRIPTION
Shifting from 1st to 5th is performed in combination with the ON and OFF operations of the shift solenoid valves S1, S2, SR, SL1 and SL2, which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be driven smoothly (Click here).| DTC No. |
DTC Detection Conditions |
Trouble Areas |
| P0973 |
ECM detects short in solenoid valve S1 circuit 2 times when solenoid valve S1 is operated. (1-trip detection logic) |
|
| P0974 |
ECM detects open in solenoid valve S1 circuit 2 times when solenoid valve S1 is not operated. (1-trip detection logic) |
|
MONITOR DESCRIPTION
These DTCs indicate an open or short in the shift solenoid valve S1 circuit. When there is an open or short circuit in any shift solenoid valve circuits, the ECM detects the problem, illuminates the MIL and stores the DTC. When the shift solenoid valve S1 is ON, if the resistance is 8 Ω or less, the ECM determines that there is a short malfunction in the shift solenoid valve S1 circuit.When the shift solenoid valve S1 is OFF, if the resistance is 100 kΩ or more, the ECM determines that the shift solenoid valve S1 circuit is open (Click here).
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- The shift solenoid valve S1 is turned on/off normally when the shift lever is in the D position:
Gearshift controlled by ECM
1st
2nd
3rd
4th
5th
Shift solenoid valve S1
ON
ON
OFF
OFF
OFF
| 1. INSPECT TRANSMISSION WIRE (S1) |
Disconnect the transmission wire connector from the transmission.

Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
8 (S1) - Body ground
11 to 15 Ω at 20°C (68°F)
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
Connect the transmission wire connector to the transmission.

Disconnect the ECM connector.
Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
B2-11 (S1) - Body ground
11 to 15 Ω at 20°C (68°F)
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE S1 |
Remove the shift solenoid valve S1.

Measure the resistance.
- Standard resistance:
Tester Connection
Specified Condition
Solenoid Connector (S1) - Solenoid Body (S1)
11 to 15 Ω at 20°C (68°F)
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
- OK:
- The solenoid makes operating sounds.
|
|
||||
| OK | ||
| ||