2011-2016 FJ Cruiser · Service Manual TRANSMISSION

P0976 Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2)

Diagnostic trouble codes · Vehicles built Jul 2007 – Jul 2009

Also covers:

Versions by build date: Jul 2007 – Jul 2009 from Aug 2009

DESCRIPTION

Shifting from 1st to 5th is performed in combination with the ON and OFF operations of the shift solenoid valves S1, S2, SR, SL1 and SL2, which are controlled by the ECM. If an open or short circuit occurs in any of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valve to allow the vehicle to be driven smoothly (Click here).
DTC No.
DTC Detection Conditions
Trouble Areas
P0976
ECM detects short in solenoid valve S2 circuit 2 times when solenoid valve S2 is operated. (1-trip detection logic)
  1. Short in shift solenoid valve S2 circuit
  2. Shift solenoid valve S2
  3. ECM
P0977
ECM detects open in solenoid valve S2 circuit 2 times when solenoid valve S2 is not operated. (1-trip detection logic)
  1. Open in shift solenoid valve S2 circuit
  2. Shift solenoid valve S2
  3. ECM

MONITOR DESCRIPTION

These DTCs indicate an open or short in the shift solenoid valve S2 circuit. When there is an open or short circuit in any shift solenoid valve circuits, the ECM detects the problem, illuminates the MIL and stores the DTC. When the shift solenoid valve S2 is ON, if the resistance is 8 Ω or less, the ECM determines that there is a short malfunction in the shift solenoid valve S2 circuit.
When the shift solenoid valve S2 is OFF, if the resistance is 100 kΩ or more, the ECM determines that the shift solenoid valve S2 circuit is open (Click here).

WIRING DIAGRAM

C162615E07

INSPECTION PROCEDURE


HINT:
The shift solenoid valve S2 is turned on/off normally when the shift lever is in the D position:
Gearshift controlled by ECM
1st
2nd
3rd
4th
5th
Shift solenoid valve S2
OFF
ON
ON
OFF
OFF


1. INSPECT TRANSMISSION WIRE (S2)

  1. C110342E81
    Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    15 (S2) - Body ground
    11 to 15 Ω at 20°C (68°F)



NG
Go to step 3
OK


2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

  1. G035616E64
    Connect the transmission wire connector to the transmission.

  1. Disconnect the ECM connector.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    B2-10 (S2) - Body ground
    11 to 15 Ω at 20°C (68°F)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)

3. INSPECT SHIFT SOLENOID VALVE S2

  1. A110987E04
    Remove the shift solenoid valve S2.

  1. Measure the resistance.

    Standard resistance:
    Tester Connection
    Specified Condition
    Solenoid Connector (S2) - Solenoid Body (S2)
    11 to 15 Ω at 20°C (68°F)

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid makes operating sounds.



NG
REPLACE SHIFT SOLENOID VALVE S2 (Click here)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)


← P0973 Shift Solenoid "A" Control Circuit Low (Shift Solenoid Valve S1) (+ P0974) (from Aug 2009)P0976 Shift Solenoid "B" Control Circuit Low (Shift Solenoid Valve S2) (+ P0977) (from Aug 2009) →