P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)
Diagnostic trouble codes · Vehicles built from Aug 2009
Versions by build date: Jul 2007 – Nov 2007 Dec 2007 – Jul 2009 from Aug 2009
DESCRIPTION
Refer to DTC P2714 (Click here).| DTC No. |
DTC Detection Conditions |
Trouble Areas |
| P2716 |
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic) |
|
MONITOR DESCRIPTION
When an open or short is detected in the linear solenoid valve (SLT) circuit, the ECM interprets this as a fault.The ECM turns on the MIL and stores the DTC.
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SLT) |
Disconnect the transmission wire connector from the transmission.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
14 (SLT+) - 6 (SLT-)
20°C (68°F)
5.0 to 5.6 Ω
14 (SLT+) - Body ground
Always
10 kΩ or higher
6 (SLT-) - Body ground
Always
10 kΩ or higher
Text in Illustration *1
Component without harness connected:
(Transmission Wire)
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
Connect the transmission wire connector to the transmission.

Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
B48-34 (SLT+) - B48-35 (SLT-)
20°C (68°F)
5.0 to 5.6 Ω
B48-34 (SLT+) - Body ground
Always
10 kΩ or higher
B48-35 (SLT-) - Body ground
Always
10 kΩ or higher
Text in Illustration *1
Rear view of wire harness connector:
(to ECM)
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SLT |
Remove the shift solenoid valve SL1.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
1 - 2
20°C (68°F)
5.0 to 5.6 Ω
Text in Illustration *1
Component without harness connected:
(Shift Solenoid Valve SL1)
Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.
- OK:
- The solenoid makes operating sounds.
|
|
||||
| OK | ||
| ||