2011-2016 FJ Cruiser · Service Manual TRANSMISSION

P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

Diagnostic trouble codes · Vehicles built from Aug 2009

Versions by build date: Jul 2007 – Nov 2007 Dec 2007 – Jul 2009 from Aug 2009

DESCRIPTION

Refer to DTC P2714 (Click here).
DTC No.
DTC Detection Conditions
Trouble Areas
P2716
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic)
  1. Open or short in shift solenoid valve SLT circuit
  2. Shift solenoid valve SLT
  3. ECM

MONITOR DESCRIPTION

When an open or short is detected in the linear solenoid valve (SLT) circuit, the ECM interprets this as a fault.
The ECM turns on the MIL and stores the DTC.

WIRING DIAGRAM

C186142E10

INSPECTION PROCEDURE


1. INSPECT TRANSMISSION WIRE (SLT)

  1. C213109E07
    Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    14 (SLT+) - 6 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    14 (SLT+) - Body ground
    Always
    10 kΩ or higher
    6 (SLT-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Component without harness connected:
    (Transmission Wire)



NG
Go to step 3
OK


2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

  1. C213114E02
    Connect the transmission wire connector to the transmission.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    B48-34 (SLT+) - B48-35 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    B48-34 (SLT+) - Body ground
    Always
    10 kΩ or higher
    B48-35 (SLT-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Rear view of wire harness connector:
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)

3. INSPECT SHIFT SOLENOID VALVE SLT

  1. C204845E01
    Remove the shift solenoid valve SL1.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

    Text in Illustration 
    *1
    Component without harness connected:
    (Shift Solenoid Valve SL1)

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes operating sounds.



NG
REPLACE SHIFT SOLENOID VALVE SLT (Click here)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)


← P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) (Dec 2007 – Jul 2009)P2740 Transmission Fluid Temperature Sensor "B" Circuit (+ P2742, P2743) (Jul 2007 – Jul 2009) →