Using a screwdriver, remove the generator pulley cap.
2.
REMOVE GENERATOR CLUTCH PULLEY
Mount the generator in a vise between aluminum plates.
Install SST (A) and (B) to the generator with clutch pulley as shown in the illustration.
SST
09820-63021
Text in Illustration
*1
Rotor Shaft
NOTICE:
Securely attach SST to the generator with clutch pulley and generator rotor shaft.
Use a wrench to hold SST (A) and turn SST (B) counterclockwise to loosen the generator with clutch pulley.
NOTICE:
Be careful as the generator with clutch pulley or generator rotor shaft may be damaged if the position of SST is not securely maintained while performing this operation.
Text in Illustration
*a
Hold
Turn
Remove SST from the generator.
Remove the generator with clutch pulley from the rotor shaft.
3.
REMOVE GENERATOR REAR END COVER
Remove the nut and cord clamp.
Remove the 3 nuts and generator rear end cover.
4.
REMOVE GENERATOR TERMINAL INSULATOR
Remove the terminal insulator from the generator coil.
5.
REMOVE GENERATOR BRUSH HOLDER ASSEMBLY
Remove the 2 screws and brush holder from the generator coil.