Home › TRANSMISSION · A750F AUTOMATIC TRANSMISSION › AUTOMATIC TRANSMISSION SYSTEM

DTC    P2716    Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

for Preparation Click here


DESCRIPTION

Refer to DTC P2714 (Click here).

DTC No.
DTC Detection Conditions
Trouble Areas
P2716
Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
  1. Open or short in shift solenoid valve SLT circuit
  2. Shift solenoid valve SLT
  3. ECM

MONITOR DESCRIPTION

When an open or short is detected in the linear solenoid valve (SLT) circuit, the ECM interprets this as a fault.
The ECM turns on the MIL and stores the DTC.

MONITOR STRATEGY


Related DTCs
P2716: Shift solenoid valve SLT/Range check
Required sensors/Components
Shift solenoid valve SLT
Frequency of operation
Continuous
Duration
1 second
MIL operation
Immediate
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the following DTCs are not present.
None
Ignition switch
ON
Starter
OFF
Solenoid current cut status
Not cut
Battery voltage
11 V or more
CPU command duty ratio to SLT
19% or more

TYPICAL MALFUNCTION THRESHOLDS


Solenoid voltage monitor signal from solenoid driver MIC
No signal

COMPONENT OPERATING RANGE


Output signal duty
Less than 100%

WIRING DIAGRAM


C186142E10


INSPECTION PROCEDURE

NOTICE:
Perform the universal trip to clear permanent DTCs (Click here).

1.INSPECT TRANSMISSION WIRE (SLT)


    C213109E07
  1. Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    14 (SLT+) - 6 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    14 (SLT+) - Body ground
    Always
    10 kΩ or higher
    6 (SLT-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Component without harness connected:
    (Transmission Wire)



NG
Go to step 3
OK


2.CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    C213114E02
  1. Connect the transmission wire connector to the transmission.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    B48-34 (SLT+) - B48-35 (SLT-)
    20°C (68°F)
    5.0 to 5.6 Ω
    B48-34 (SLT+) - Body ground
    Always
    10 kΩ or higher
    B48-35 (SLT-) - Body ground
    Always
    10 kΩ or higher

    Text in Illustration 
    *1
    Rear view of wire harness connector:
    (to ECM)



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)  

3.INSPECT SHIFT SOLENOID VALVE SLT


    C204845E01
  1. Remove the shift solenoid valve SLT.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

    Text in Illustration 
    *1
    Component without harness connected:
    (Shift Solenoid Valve SLT)

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes operating sounds.



NG
REPLACE SHIFT SOLENOID VALVE SLT
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)