2014-2019 Hiace · Service Manual ENGINE

INSPECTION

Inspection · Vehicles built from Oct 2014


INSPECT ELECTRIC EGR CONTROL VALVE ASSEMBLY

  1. Inspect the vacuum regulating valve.

    1. A172245E01
      Measure the resistance between the terminals.

      Standard Resistance:
      Tester Connection
      Condition
      Specified Condition
      1 - 2
      20°C (68°F)
      11 to 13 Ω

    2. A242066E01
      Apply battery voltage across the terminals and check that air flows from each port.

      Standard:
      Inspection Condition
      Port
      Air Flow
      Battery voltage not applied
      E - Ventilation port
      Air flows
      Battery voltage not applied
      Ventilation port - F
      E - F
      Air does not flow
      Battery voltage applied
      E - F
      Air flows
      Battery voltage applied
      Ventilation port - E
      Ventilation port - F
      Air does not flow

      If the result is not as specified, replace the EGR valve.

  1. A245485E01
    Inspect the EGR valve.

    HINT:
    Install a cap to block the other port.


    1. When a vacuum of 26.7 kPa (200 mmHg, 7.87 in.Hg) is applied to the diaphragm chamber, check that the shaft rises and that air flows out.

    2. Maintaining the above conditions, check again that there are no leaks and that the shaft does not lower.

    3. Check that the valve is not stuck and does not have heavy carbon deposits.
      If the result is not as specified, replace the EGR valve.

  1. Inspect the EGR valve position sensor.

    1. A172247
      Using an ohmmeter, measure the resistance between terminals 1 (VC) and 2 (E2) of the EGR valve position sensor.

      Standard resistance:
      4.0 to 6.0 kΩ at 20°C (68°F)

      If the result is not as specified, replace the EGR valve.

    2. A245486E01
      Create a vacuum in the diaphragm chamber. Measure the resistance between terminals 3 (EGLS) and 2 (E2) of the lift sensor when the valve is fully opened and fully closed.

      Standard Resistance:
      EGR Valve Condition
      Specified Condition
      Fully opened
      0.1 to 2.0 kΩ at 20°C (68°F)
      Fully closed
      2.2 to 7.5 kΩ at 20°C (68°F)

      HINT:
      1. Install a cap to block the other port.
      2. The resistance increases in proportion to the opening angle of the EGR valve.

      If the result is not as specified, replace the EGR valve.

← REMOVAL (from Oct 2014)INSTALLATION (from Oct 2014) →