INSPECTION
Inspection · Vehicles built from Oct 2014
| INSPECT ELECTRIC EGR CONTROL VALVE ASSEMBLY |
Inspect the vacuum regulating valve.
Check that there is continuity between the terminals.

- Standard resistance:
- 11 to 13 Ω (20°C)
Apply battery voltage across the terminals, and check that air flows from each port.
- Standard:
Measuring Condition
Measuring Port
Airflow
No continuity
E←→Ventilation port
Airflows
No continuity
Ventilation port←→F
E←→F
Air does not flows
Continuity
E←→F
Airflows
Continuity
Ventilation port←→E
Ventilation port←→F
Air does not flows
Inspect the EGR valve.
When a vacuum of 26.7 kPa (200 mmHg, 7.87 in.Hg) is applied to the diaphragm chamber, check that the shaft rises and that air flows out.

Maintaining the above conditions, check again that there are no leaks and that the shaft does not lower.
Check that the valve is not stuck and does not have heavy carbon deposits.
If the result is not as specified, replace the EGR valve.
Inspect the EGR valve position sensor.
Using an ohmmeter, measure the resistance between terminals 1 (VC) and 2 (E2) of the EGR valve position sensor.

- Standard resistance:
- 4.0 to 6.0 kΩ at 20°C (68°F)
Create a vacuum in the diaphragm chamber. Measure the resistance between terminals 3 (EGLS) and (E2) of the lift sensor when the valve is fully opened and fully closed.

- Standard resistance:
EGR Valve Condition
Specified Condition
Fully opened
2.0 to 7.0 kΩ at 20°C (68°F)
Fully closed
0.1 to 2.5 kΩ at 20°C (68°F)
- HINT:
- The resistance increases in proportion to the opening angle of the EGR valve.