When the ignition switch is turned to ON, the battery voltage is applied to terminal IGSW of the ECM. The MREL output signal from ECM causes a current to flow to the coil, closing the contacts of the EFI MAIN relay and supplying power to terminal +B of the ECM.
WIRING DIAGRAM
INSPECTION PROCEDURE
NOTICE:
After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
Inspect the fuses of circuits related to this system before performing the following inspection procedure.
1. CHECK HARNESS AND CONNECTOR (ECM - BODY GROUND)
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
Standard Resistance::
Tester Connection
Condition
Specified Condition
D99-109 (E1) - Body ground
Always
Below 1 Ω
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
2. CHECK TERMINAL VOLTAGE (IGSW TERMINAL VOLTAGE)
Disconnect the ECM connector.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.