Refer to "SRS Warning Light Remains ON" (Click here).
WIRING DIAGRAM
Refer to "SRS Warning Light Remains ON" (Click here).
INSPECTION PROCEDURE
NOTICE:
When disconnecting the cable from the negative (-) battery terminal while performing repairs, some systems need to be initialized after the cable is reconnected (Click here).
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
1. CHECK BATTERY
Measure the voltage of the battery.
Standard voltage:
11 to 14 V
HINT:
It may be possible to tell whether the battery is discharged by operating the horn.
If the voltage is below 11 V, recharge or replace the battery before proceeding to the next step.
NG
REPLACE OR RECHARGE BATTERY
OK
2. CHECK CONNECTORS
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Check that the connectors are properly connected to the combination meter.
OK:
The connectors are properly connected.
NG
CONNECT CONNECTORS PROPERLY
OK
3. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY
- BATTERY AND BODY GROUND)
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch to ON.
Measure the voltage according to the value(s) in the table below.
Standard Voltage:
Tester Connection
Condition
Specified Condition
H20-2 (IG1) - H20-21 (E1)
Ignition switch ON
11 to 14 V
H20-1 (L) - H20-21 (E1)
Always
11 to 14 V
Measure the resistance according to the value(s) in the table below.
Standard Resistance:
Tester Connection
Condition
Specified Condition
H20-21 (E1) - Body ground
Always
Below 1 Ω
Text in Illustration
*a
Front view of wire harness connector (to Combination Meter Assembly)
NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK
4. CHECK SRS WARNING LIGHT (SHORT TO GROUND)
Turn the ignition switch off.
Disconnect the cable from the negative (-) battery terminal, and wait for at least 90 seconds.
Connect the connector to the combination meter.
Connect the cable to the negative (-) battery terminal, and wait for at least 2 seconds.
Turn the ignition switch ON.
Check the SRS warning light condition.
NOTICE:
Make sure that nobody is in the vehicle.
OK:
After the primary check period, the SRS warning light goes off for approximately 10 seconds and then remains on.
HINT:
The primary check period is approximately 6 seconds after the ignition switch is turned to ON.