2014-2019 Hiace · Service Manual ENGINE

INSPECTION

Inspection · Vehicles built from Oct 2014


INSPECT CRANKSHAFT POSITION SENSOR

  1. A074841
    Measure the resistance between the terminals.

    Standard resistance:
    Temperature
    Specified Condition
    Cold
    1,630 to 2,740 Ω
    Hot
    2,065 to 3,225 Ω

    HINT:
    In the table above, the terms "cold" and "hot" refer to the temperature of the coils. "Cold" means approximately -10 to 50°C (14 to 122°F). "Hot" means approximately 50 to 100°C (122 to 212°F).

    If the resistance is not as specified, replace the sensor.

← REMOVAL (from Oct 2014)INSTALLATION (from Oct 2014) →