2014-2019 Hiace · Service Manual TRANSMISSION

P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)

Diagnostic trouble codes · Vehicles built from Oct 2014

Also covers:

DESCRIPTION

The shift solenoid valve SL is turned "ON" and "OFF" by signals from the ECM in order to control the hydraulic pressure operation, the lock-up relay valve, which then the controls operation of the lock-up clutch.
DTC No.
DTC Detection Condition
Trouble Area
P2769
ECM detects short in solenoid valve SL circuit 1 time when solenoid valve SL is operated (2-trip detection logic)
  1. Short in shift solenoid valve SL circuit
  2. Shift solenoid valve SL
  3. ECM
P2770
ECM detects open in solenoid valve SL circuit 1 time when solenoid valve SL is not operated (2-trip detection logic)
  1. Open in shift solenoid valve SL circuit
  2. Shift solenoid valve SL
  3. ECM

MONITOR DESCRIPTION

Based on the signals from the Throttle Position Sensor, the Airflow Meter and the Crankshaft Position Sensor, the ECM sends a signal to the SL Solenoid Valve to regulate the hydraulic pressure and provide smoother gearshifts. The shift-solenoid valve SL responds to commands from the ECM. The valve controls the lock-up relay valve to perform the torque-converter lock-up function. If the ECM detects an open or short circuit for shift-solenoid SL, it will illuminate the MIL.

WIRING DIAGRAM

C294508E09

INSPECTION PROCEDURE


1. INSPECT TRANSMISSION WIRE (SL)

  1. C214964E17
    Disconnect the transmission wire connector from the transmission.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    7 - Body ground
    11 to 15 Ω

Text in Illustration 
*a
Component without harness connected
(Transmission Wire)


NG
Go to step 3
OK


2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

  1. C302055E16
    Connect the transmission connector to the transmission.

  1. Disconnect the connector from the ECM.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    D97-61 (SL) - Body ground
    11 to 15 Ω

Text in Illustration 
*a
Front view of wire harness connector
(to ECM)


NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM

3. INSPECT SHIFT SOLENOID VALVE SL

  1. G038834E03
    Remove the shift solenoid valve SL.

  1. Measure the resistance according to the value(s) in the table below.

    Resistance:
    Tester Connection
    Specified Condition
    20°C (68°F)
    Solenoid Connector (SL) - Solenoid Body (SL)
    11 to 15 Ω

  1. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

    OK:
    The solenoid makes an operating sound.

Text in Illustration 
*a
Component without harness connected
(Shift Solenoid Valve SL)


NG
REPLACE SHIFT SOLENOID VALVE SL
OK

REPAIR OR REPLACE TRANSMISSION WIRE


← P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT) (from Oct 2014)Stop Light Switch Circuit (from Oct 2014) →