P2769 Short in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)
Diagnostic trouble codes · Vehicles built from Oct 2014
Also covers:
- P2770 Open in Torque Converter Clutch Solenoid Circuit (Shift Solenoid Valve SL)
DESCRIPTION
The shift solenoid valve SL is turned "ON" and "OFF" by signals from the ECM in order to control the hydraulic pressure operation, the lock-up relay valve, which then the controls operation of the lock-up clutch.| DTC No. |
DTC Detection Condition |
Trouble Area |
| P2769 |
ECM detects short in solenoid valve SL circuit 1 time when solenoid valve SL is operated (2-trip detection logic) |
|
| P2770 |
ECM detects open in solenoid valve SL circuit 1 time when solenoid valve SL is not operated (2-trip detection logic) |
|
MONITOR DESCRIPTION
Based on the signals from the Throttle Position Sensor, the Airflow Meter and the Crankshaft Position Sensor, the ECM sends a signal to the SL Solenoid Valve to regulate the hydraulic pressure and provide smoother gearshifts. The shift-solenoid valve SL responds to commands from the ECM. The valve controls the lock-up relay valve to perform the torque-converter lock-up function. If the ECM detects an open or short circuit for shift-solenoid SL, it will illuminate the MIL.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT TRANSMISSION WIRE (SL) |
Disconnect the transmission wire connector from the transmission.

Measure the resistance according to the value(s) in the table below.
- Resistance:
Tester Connection
Specified Condition
20°C (68°F)
7 - Body ground
11 to 15 Ω
| *a |
Component without harness connected (Transmission Wire) |
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM) |
Connect the transmission connector to the transmission.

Disconnect the connector from the ECM.
Measure the resistance according to the value(s) in the table below.
- Resistance:
Tester Connection
Specified Condition
20°C (68°F)
D97-61 (SL) - Body ground
11 to 15 Ω
| *a |
Front view of wire harness connector (to ECM) |
|
|
||||
| OK | ||
| ||
| 3. INSPECT SHIFT SOLENOID VALVE SL |
Remove the shift solenoid valve SL.

Measure the resistance according to the value(s) in the table below.
- Resistance:
Tester Connection
Specified Condition
20°C (68°F)
Solenoid Connector (SL) - Solenoid Body (SL)
11 to 15 Ω
Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.
- OK:
- The solenoid makes an operating sound.
| *a |
Component without harness connected (Shift Solenoid Valve SL) |
|
|
||||
| OK | ||
| ||