2014-2019 Hiace · Service Manual SERVICE SPECIFICATIONS

SERVICE DATA

Specifications · Vehicles built Oct 2014 – Dec 2014

Versions by build date: Oct 2014 – Dec 2014 from Jan 2015

Charging circuit without load
Standard amperage: 10 A or less
Standard voltage: 12.1 to 15.4 V
Charging circuit with load
Standard amperage: 30 A or more
Brush length
Standard: 10.5 mm (0.413 in.)
Minimum: 4.5 mm (0.177 in.)
Generator rotor assembly
Coil resistance: 2.3 to 2.7 Ω at 20°C (68°F)
Standard slip ring diameter: 14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum slip ring diameter: 14.0 mm (0.551 in.)
Battery thermometer sensor
Standard resistance: 1.91 to 2.05 kΩ at 24 to 26°C (75 to 79 °F)
← TORQUE SPECIFICATIONS (from Oct 2014)SERVICE DATA (from Jan 2015) →