2014-2019 Hiace · Service Manual HEATER & AIR CONDITIONING SYSTEM

B1412 Ambient Temperature Sensor Circuit

Diagnostic trouble codes · Vehicles built Apr 2016 – Dec 2016

Versions by build date: Oct 2014 – Dec 2014 Jan 2015 – Mar 2016 Apr 2016 – Dec 2016 from Jan 2017

DESCRIPTION

The cooler thermistor (ambient temperature sensor) is installed in the front part of the condenser assembly with receiver to detect the ambient temperature and control the air conditioning auto mode. The sensor connected to the air conditioning amplifier assembly detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The combination meter assembly applies a voltage (5 V) to the cooler thermistor (ambient temperature sensor) and reads voltage changes as changes in the resistance of the cooler thermistor (ambient temperature sensor). The combination meter assembly sends the signal to the air conditioning amplifier assembly via CAN communication.
DTC Code
DTC Detection Condition
Trouble Area
B1412
An open or short in the cooler thermistor (ambient temperature sensor) circuit.
  1. CAN communication system
  2. Cooler thermistor (ambient temperature sensor)
  3. Harness or connector
  4. Combination meter assembly
  5. Air conditioning amplifier assembly

WIRING DIAGRAM

E293713E01

INSPECTION PROCEDURE


1. CHECK CAN COMMUNICATION SYSTEM
  1. Use the GTS to check if the CAN communication system is functioning normally (Click here).

    Result 
    Result
    Proceed to
    CAN DTC is not output
    A
    CAN DTC is output
    B



B
GO TO CAN COMMUNICATION SYSTEM (Click here)
A


2. READ VALUE USING GTS (AMBIENT TEMPERATURE SENSOR)
  1. Use the Data List to check if the cooler thermistor (ambient temperature sensor) is functioning properly (Click here).

    Air Conditioner 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temp Sensor
    Cooler thermistor (ambient temperature sensor) /
    Min: -23.3°C (-9.94°F)
    Max: 65.95°C (150.71°F)
    Actual ambient temperature displayed
    Open in the circuit: -23.3°C (-9.94°F).
    Short in the circuit: 65.95°C (150.71°F).

    OK:
    The display is as specified in the normal condition column.

    Result 
    Result
    Proceed to
    OK (When troubleshooting according to problem symptoms table)
    A
    OK (When troubleshooting according to the DTC)
    B
    NG
    C



B
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)

C
Go to step 3
A

PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

3. READ VALUE USING GTS (AMBIENT TEMPERATURE)
  1. Use the Data List to check if the cooler thermistor (ambient temperature sensor) is functioning properly (Click here).

    Combination Meter 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Ambient Temperature
    Outside temperature / Min.: -40°C (-40°F), Max.: 87.5°C (189.5°F)
    Almost the same as actual outside temperature
    -

    OK:
    The display is as specified in the normal condition column.



NG
Go to step 5
OK


4. CHECK COMBINATION METER ASSEMBLY
  1. Replace the combination meter assembly (Click here).

  1. Clear the DTC (Click here).

  1. Check for DTCs (Click here).

    OK:
    DTC B1412 is not output.



NG
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)
OK

END (COMBINATION METER ASSEMBLY IS DEFECTIVE)

5. INSPECT COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR)
  1. Remove the cooler thermistor (ambient temperature sensor).

  1. Inspect the cooler thermistor (ambient temperature sensor) (Click here).



NG
REPLACE COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR)
OK


6. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - AMBIENT TEMPERATURE SENSOR)
  1. Disconnect the A14 cooler thermistor (ambient temperature sensor) connector.

  1. Disconnect the H20 combination meter assembly connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard Resistance:
    Tester Connection
    Condition
    Specified Condition
    A14-1 - H20-37 (TX1-)
    Always
    Below 1 Ω
    A14-2 - H20-36 (TX1+)
    H20-37 (TX1-) - Body ground
    Always
    10 kΩ or higher
    H20-36 (TX1+) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY (Click here)


← B1412 Ambient Temperature Sensor Circuit (Jan 2015 – Mar 2016)B1412 Ambient Temperature Sensor Circuit (from Jan 2017) →