B1412 Ambient Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built Jan 2015 – Mar 2016
Versions by build date: Oct 2014 – Dec 2014 Jan 2015 – Mar 2016 Apr 2016 – Dec 2016 from Jan 2017
DESCRIPTION
The cooler thermistor (ambient temperature sensor) is installed in the front part of the condenser assembly with receiver to detect the ambient temperature and control the air conditioning auto mode. The sensor connected to the air conditioning amplifier assembly detects fluctuations in the ambient temperature. This data is used for controlling the room temperature. The sensor sends a signal to the air conditioning amplifier assembly. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The combination meter assembly applies a voltage (5 V) to the cooler thermistor (ambient temperature sensor) and reads voltage changes as changes in the resistance of the cooler thermistor (ambient temperature sensor). The combination meter assembly sends the signal to the air conditioning amplifier assembly via CAN communication.
| DTC Code |
DTC Detection Condition |
Trouble Area |
| B1412 |
An open or short in the cooler thermistor (ambient temperature sensor) circuit. |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. CHECK CAN COMMUNICATION SYSTEM |
Use the GTS to check if the CAN communication system is functioning normally (Click here).
Result Result
Proceed to
CAN DTC is not output
A
CAN DTC is output
B
|
|
||||
| A | |
| 2. READ VALUE USING GTS (AMBIENT TEMPERATURE SENSOR) |
Use the Data List to check if the cooler thermistor (ambient temperature sensor) is functioning properly (Click here).
Air Conditioner Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Ambient Temp Sensor
Cooler thermistor (ambient temperature sensor) /
Min: -23.3°C (-9.94°F)
Max: 65.95°C (150.71°F)
Actual ambient temperature displayed
Open in the circuit: -23.3°C (-9.94°F).
Short in the circuit: 65.95°C (150.71°F).
- OK:
- The display is as specified in the normal condition column.
Result Result
Proceed to
OK (When troubleshooting according to problem symptoms table)
A
OK (When troubleshooting according to the DTC)
B
NG
C
|
|
||||
|
|
||||
| A | ||
| ||
| 3. READ VALUE USING GTS (AMBIENT TEMPERATURE) |
Use the Data List to check if the cooler thermistor (ambient temperature sensor) is functioning properly (Click here).
Combination Meter Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Ambient Temperature
Outside temperature / Min.: -40°C (-40°F), Max.: 87.5°C (189.5°F)
Almost the same as actual outside temperature
-
- OK:
- The display is as specified in the normal condition column.
|
|
||||
| OK | |
| 4. CHECK COMBINATION METER ASSEMBLY |
Replace the combination meter assembly (Click here).
Clear the DTC (Click here).
Check for DTCs (Click here).
- OK:
- DTC B1412 is not output.
|
|
||||
| OK | ||
| ||
| 5. INSPECT COOLER THERMISTOR (AMBIENT TEMPERATURE SENSOR) |
Remove the cooler thermistor (ambient temperature sensor).
Inspect the cooler thermistor (ambient temperature sensor) (Click here).
|
|
||||
| OK | |
| 6. CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - AMBIENT TEMPERATURE SENSOR) |
Disconnect the A14 cooler thermistor (ambient temperature sensor) connector.
Disconnect the H20 combination meter assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A14-1 - H20-37 (TX1-)
Always
Below 1 Ω
A14-2 - H20-36 (TX1+)
H20-37 (TX1-) - Body ground
Always
10 kΩ or higher
H20-36 (TX1+) - Body ground
|
|
||||
| OK | ||
| ||