Power Slide Door RH does not Operate When Using Inside / Outside Handle
Circuit diagnosis · Vehicles built from Oct 2014
DESCRIPTION
The door control relay assembly controls the power slide door and activates the slide door motor unit RH. When the door handle is pulled, the power slide door automatically moves to the fully open position.WIRING DIAGRAM
(Click here)INSPECTION PROCEDURE
| 1. INSPECT SLIDE DOOR LOCK REMOTE CONTROL ASSEMBLY RH |
Remove the slide door lock remote control assembly (Click here).

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Handle Condition
Specified Condition
1 - 3
Handle in initial position
10 kΩ or higher
2 - 3
1 - 3
Handle pulled
Below 1 Ω
2 - 3
|
|
||||
| OK | |
| 2. INSPECT REAR DOOR WIRE RH |
Disconnect the ci1 and fc1 rear door wire RH connectors.

Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A-8 - B-11
Always
Below 1 Ω
A-12 - B-17
Always
Below 1 Ω
A-10 - B-16
Always
Below 1 Ω
Text in Illustration *a
Rear Door Wire RH
(Door Control Relay Assembly Side)
*b
Rear Door Wire RH
(Slide Door Lock Remote Control Assembly RH Side)
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (SLIDE DOOR LOCK REMOTE CONTROL RH - DOOR CONTROL RELAY ASSEMBLY) |
Disconnect the f4 slide door lock remote control RH connector.
Disconnect the I4 door control relay assembly connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
f4-2 - I4-20 (MPX2)
Always
Below 1 Ω
f4-1 - I4-8 (MPX1)
Always
Below 1 Ω
f4-3 - I4-13 (OSG)
Always
Below 1 Ω
f4-2 or I4-20 (MPX2) - Body ground
Always
10 kΩ or higher
f4-1 or I4-8 (MPX1) - Body ground
Always
10 kΩ or higher
f4-3 or I4-13 (OSG) - Body ground
Always
10 kΩ or higher
|
|
||||
| OK | ||
| ||