REMOVAL
Removal / installation · Vehicles built from Jan 2017
| 1. REMOVE UREA TANK SUB-ASSEMBLY |
| 2. REMOVE UREA PUMP |
Apply a co-rotation prevention check mark to the urea pump from the urea tank sub-assembly.

Text in Illustration *a
Co-rotation Prevention Check Mark
- NOTICE:
- The urea tank sub-assembly cutout is attached to protrusion on the urea tube with heater assembly.
- If the urea pump and urea tank sub-assembly are not firmly attached and the urea pump gauge retainer is rotated, the urea pump will co-rotate and result in urea pump being damaged.
- Make sure to apply co-rotation prevention check mark to prevent the urea pump from co-rotating.
- The urea tank sub-assembly cutout is attached to protrusion on the urea tube with heater assembly.
Set 4 SSTs (claw sets) to the urea pump gauge retainer and temporarily install.

- SST
- 09808-14031
(09808-01080, 09808-01090, 09808-01100)
Text in Illustration *1
Urea Pump gauge Retainer
*a
SST (Claw Set)
*b
Rib
*c
Cutout
*d
SST (Claw Set) Incorrect Installation Point (Rotational Start Point Mark of Urea Pump Gauge Retainer)
- NOTICE:
- Align the cutout of SST (claw set) to the rib of the urea pump gauge retainer.
- Do not place SST on the rotational start paint mark of the urea pump gauge retainer, otherwise SST (claw set) cannot be set correctly.
- Align the cutout of SST (claw set) to the rib of the urea pump gauge retainer.
While firmly pressing the claw of SST into rib of the urea pump gauge retainer, tighten the bolt.

Text in Illustration *1
Urea Pump Gauge Retainer
*a
SST (Claw Set)
*b
Press


Pinch


SST (Bolt)
Temporarily install SST (plate) to SST (claw set) with 4 SSTs (bolts).

Text in Illustration *a
SST (Plate)
*b
SST (Claw Set)


SST (Bolt)
Adjust the position of SST (plate) so that the setting hole of SST (handle) aligns with the center of the urea pump gauge retainer.

Text in Illustration *a
Center of Urea Pump Gauge Retainer
*b
SST (Plate)
While firmly pressing SST (claw set) into rib of the urea pump gauge retainer, tighten SST (bolt).

Text in Illustration *1
Urea Pump Gauge Retainer
*a
SST (Plate)
*b
SST (Claw Set)
*c
SST (Bolt)
*d
Rib


Press
Install SST (handle) to SST (plate).

- SST
- 09808-14031
(09808-01010, 09808-01020)
Text in Illustration *a
SST (Plate)
*b
SST (Handle)
*c
SST (Claw Set)


Loosen
Slowly loosen the urea pump gauge retainer by approximately 90°.
- NOTICE:
- Do not use any tools other than SST, such as screwdriver, etc.
- Do not excessive force when pressing down on SST, as urea tube with heater assembly will place excessive force on the urea pump gauge retainer and be difficult to remove, and parts may be damaged.
- Do not use an impact wrench or turn SST handle with excessive force, as parts may be damaged.
- Do not use any tools other than SST, such as screwdriver, etc.
While on person slowly loosens the urea pump gauge retainer, have another person press down the rising urea pump, securely attach the protrusion of the urea pump to the groove of the urea tank sub-assembly, and then remove the urea pump gauge retainer while making sure that the urea pump is properly aligned.
- NOTICE:
- If the urea pump gauge retainer is turned while the urea pump and urea tank sub-assembly are not correctly aligned, urea pump will move with the urea pump gauge retainer, and the urea pump and urea tank sub-assembly may both be damaged.
- Do not rotate the urea pump gauge retainer when the co-rotation prevention check mark is out of place.
- If the urea pump gauge retainer is turned while the urea pump and urea tank sub-assembly are not correctly aligned, urea pump will move with the urea pump gauge retainer, and the urea pump and urea tank sub-assembly may both be damaged.


Text in Illustration *a
SST (Plate)
*b
SST (Handle)
*c
Person in Charge of Loosening
*d
Person in Charge of Supporting
*e
Co-rotation Prevention Check Mark
-
-
Remove the urea pump from the urea tank sub-assembly.

Remove the gasket from the urea tank sub-assembly.