P204C Reductant Pressure Sensor Circuit Low
Diagnostic trouble codes · Vehicles built from Jan 2017
Also covers:
- P204D Reductant Pressure Sensor Circuit High
DESCRIPTION
Refer to DTC P208B (Click here).| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| Ignition switch ON for 3 seconds |
An open or short circuit occurs in the pressure sensor circuit for 3 seconds or more. (1 trip detection logic) |
|
| DTC Detection Drive Pattern |
DTC Detection Condition |
Trouble Area |
| Ignition switch ON for 3 seconds |
An open or short circuit occurs in the pressure sensor circuit for 3 seconds or more. (1 trip detection logic) |
|
| DTC No. |
Data List |
| P204C P204D |
Reductant Pressure |
WIRING DIAGRAM


INSPECTION PROCEDURE
- HINT:
- Read freeze frame data using the GTS. Freeze frame data records the engine condition when malfunctions are detected. When troubleshooting, freeze frame data can help determine if the vehicle was moving or stationary, if the engine was warmed up or not, and other data from the time the malfunction occurred.
| 1. READ VALUE USING GTS (REDUCTANT PRESSURE) |
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Reductant Pressure.
Read the Data List according to the display on the GTS.
Result Result
Proceed to
-50 kPa
A
900 kPa
B
|
|
||||
| A | |
| 2. READ VALUE USING GTS (CHECK FOR OPEN) |
Disconnect the pressure sensor (urea pump) connector.

Connect terminals 4 (VPSE) and 5 (PSE) of the pressure sensor (urea pump) wire harness side connector.
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Reductant Pressure.
Read the Data List according to the display on the GTS.
- OK:
- 900 kPa
Text in Illustration *a
Front view of wire harness connector
(to Pressure Sensor (Urea Pump))
|
|
||||
| OK | |
| 3. REPLACE UREA PUMP |
Replace the urea pump (Click here).
| NEXT | |
| 4. CLEAR DTC |
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Clear the DTCs (Click here).
Turn the ignition switch off and wait for at least 30 seconds.
| NEXT | |
| 5. CHECK DTC OUTPUT |
Connect the GTS to the DLC3.
Turn the ignition switch to ON and wait for 3 seconds or more.
Turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.
Confirm that the DTC is not output again.
| NEXT | ||
| ||
| 6. CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR (UREA PUMP) - UREA PUMP CONTROL ECU) |


| *a |
Front view of wire harness connector (to Pressure Sensor (Urea Pump)) |
*b |
Front view of wire harness connector (to Urea Pump Control ECU) |
Disconnect the pressure sensor (urea pump) connector.
Disconnect the urea pump control ECU connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A47-4 (VPSE) - A45-57 (VCPU)
Always
Below 1 Ω
A47-5 (PSE) - A45-56 (PU)
Always
Below 1 Ω
A47-6 (EPSE) - A45-55 (EPU)
Always
Below 1 Ω
A47-4 (VPSE) or A45-57 (VCPU) - Body ground and other terminals
Always
10 kΩ or higher
A47-5 (PSE) or A45-56 (PU) - Body ground and other terminals
Always
10 kΩ or higher
A47-6 (EPSE) or A45-55 (EPU) - Body ground and other terminals
Always
10 kΩ or higher
|
|
||||
| OK | |
| 7. REPLACE UREA PUMP CONTROL ECU |
Replace the urea pump control ECU (Click here).
|
|
||||
| 8. REPAIR OR REPLACE HARNESS OR CONNECTOR |
Repair or replace harness or connector.
|
|
||||
| 9. READ VALUE USING GTS (CHECK FOR SHORT) |
Disconnect the pressure sensor (urea pump) connector.
Connect the GTS to the DLC3.
Turn the ignition switch to ON and turn the GTS on.
Enter the following menus: Powertrain / Engine and ECT / Data List / Reductant Pressure.
Read the Data List according to the display on the GTS.
- OK:
- -50 kPa
|
|
||||
| NG | |
| 10. CHECK HARNESS AND CONNECTOR (PRESSURE SENSOR (UREA PUMP) - UREA PUMP CONTROL ECU) |


| *a |
Front view of wire harness connector (to Pressure Sensor (Urea Pump)) |
*b |
Front view of wire harness connector (to Urea Pump Control ECU) |
Disconnect the pressure sensor (urea pump) connector.
Disconnect the urea pump control ECU connector.
Measure the resistance according to the value(s) in the table below.
- Standard Resistance:
Tester Connection
Condition
Specified Condition
A47-4 (VPSE) - A45-57 (VCPU)
Always
Below 1 Ω
A47-5 (PSE) - A45-56 (PU)
Always
Below 1 Ω
A47-6 (EPSE) - A45-55 (EPU)
Always
Below 1 Ω
A47-4 (VPSE) or A45-57 (VCPU) - Body ground and other terminals
Always
10 kΩ or higher
A47-5 (PSE) or A45-56 (PU) - Body ground and other terminals
Always
10 kΩ or higher
A47-6 (EPSE) or A45-55 (EPU) - Body ground and other terminals
Always
10 kΩ or higher
|
|
||||
|
|
||||