Home › Power Source / Network › POWER DISTRIBUTION › INTEGRATION RELAY
RM35X0E _57 Power Source / Network _079061 POWER DISTRIBUTION _0384098 INTEGRATION RELAY A

POWER DISTRIBUTION  INTEGRATION RELAY  INSTALLATION  


PROCEDURE

Hide 82641 1.INSTALL NO. 1 INTEGRATION RELAY

a.
E415076

Connect the 4 connectors.


b.
E415077C02
0,0 0,0 false
V113147

Install in this Direction


Attach the claw and install the No. 1 integration relay.


Hide 82662A 2.INSTALL NO. 1 RELAY BLOCK COVER

a.
E415078C02
0,0 0,0 false
V113147

Install in this Direction


Attach the claw and guide and install the No. 1 relay block cover.


Hide 3.CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

Hide 4. INITIALIZATION AFTER RECONNECTING BATTERY TERMINAL

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART