88625
1.INSTALL NO. 1 COOLER THERMISTOR (FRONT EVAPORATOR TEMPERATURE SENSOR) (for LHD)
| *a | Fixed Part |
| *b | Sensor Part |
Install the No. 1 cooler thermistor (front evaporator temperature sensor) as shown in the illustration.
Be sure to insert the No. 1 cooler thermistor (front evaporator temperature sensor) only once because reinserting it into the same position will not allow it to be firmly secured.
When reusing the No. 1 cooler evaporator sub-assembly, insert the sensor part of the No. 1 cooler thermistor (front evaporator temperature sensor) one row from the row that had been used previously (X in the illustration).
After inserting the No. 1 cooler thermistor (front evaporator temperature sensor), do not apply excessive force to the wire.
Directly insert the No. 1 cooler thermistor (front evaporator temperature sensor), until the edge of the plastic case "a" comes into contact with the No. 1 cooler evaporator sub-assembly "b".
| Position | Measurement |
|---|---|
| A | 45 to 55 mm (1.77 to 2.17 in.) |
| B | 61.1 mm (2.41 in.) (9 Fins) |
88501
2.INSTALL NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY (for LHD)
88515
3.INSTALL COOLER EXPANSION VALVE (for LHD)
87107A
4.INSTALL HEATER RADIATOR UNIT SUB-ASSEMBLY (for LHD)
82210K
5.INSTALL AIR CONDITIONING HARNESS ASSEMBLY (for LHD Automatic Air Conditioning System)
87130D
6.INSTALL BLOWER ASSEMBLY (for LHD)
7.INSTALL AIR CONDITIONER UNIT ASSEMBLY (for LHD)
88625
8.INSTALL NO. 1 COOLER THERMISTOR (FRONT EVAPORATOR TEMPERATURE SENSOR) (for RHD)
| *A | w/o Stop and Start System |
| *B | w/ Stop and Start System |
| *a | Fixed Part |
| *b | Sensor Part |
Install the No. 1 cooler thermistor (front evaporator temperature sensor) as shown in the illustration.
Be sure to insert the No. 1 cooler thermistor (front evaporator temperature sensor) only once because reinserting it into the same position will not allow it to be firmly secured.
When reusing the No. 1 cooler evaporator sub-assembly, insert the sensor part of the No. 1 cooler thermistor (front evaporator temperature sensor) one row from the row that had been used previously (X in the illustration).
After inserting the No. 1 cooler thermistor (front evaporator temperature sensor), do not apply excessive force to the wire.
Directly insert the No. 1 cooler thermistor (front evaporator temperature sensor), until the edge of the plastic case "a" comes into contact with the No. 1 cooler evaporator sub-assembly "b".
| Position | Measurement |
|---|---|
| A | 45 to 55 mm (1.77 to 2.17 in.) |
| B | 61.1 mm (2.41 in.) (9 Fins) |
| C | 23 to 27 mm (0.91 to 1.06 in.) |
| D | 54.4 mm (2.14 in.)(8 Fins) |
88501
9.INSTALL NO. 1 COOLER EVAPORATOR SUB-ASSEMBLY (for RHD)
88515
10.INSTALL COOLER EXPANSION VALVE (for RHD)
87107A
11.INSTALL HEATER RADIATOR UNIT SUB-ASSEMBLY (for RHD)
87130D
12.INSTALL BLOWER ASSEMBLY (for RHD)
13.INSTALL AIR CONDITIONER UNIT ASSEMBLY (for RHD)