89463D
1.INSTALL NO. 2 NITROGEN OXIDES SENSOR
Install the No. 2 nitrogen oxides sensor to the sensor bracket with the 2 nuts, and attach the 2 clamps.
| *a | Torque Wrench Fulcrum Length |
Using SST, install the No. 2 nitrogen oxides sensor.
Replace with a new part if it is dropped or if it receives a strong impact.
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)): 49.2 N*m (502 kgf*cm, 36 ft.*lbf)
|
Bolt |
|
Connector |
Install the sensor bracket to the vehicle body with the 2 bolts.
Connect the connector to the No. 2 nitrogen oxides sensor.
Attach the 2 clamps and connect the No. 4 exhaust gas temperature sensor to the sensor bracket.
Connect the connector to the No. 4 exhaust gas temperature sensor.
|
Bolt |
|
Clip |
Install the step plate cover sub-assembly RH with the 4 bolts and 4 clips.
89463C
2.INSTALL NO. 1 NITROGEN OXIDES SENSOR
Install the No. 1 nitrogen oxides sensor with the 2 nuts to the exhaust sensor clamp bracket, and attach the clamp (cable tie).
| *a | Torque Wrench Fulcrum Length |
Using SST, install the No. 1 nitrogen oxides sensor.
Replace with a new part if it is dropped or if it receives a strong impact.
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When using SST (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 255 mm (10.0 in.)): 49.2 N*m (502 kgf*cm, 36 ft.*lbf)
25051
3.INSTALL EXHAUST MANIFOLD CONVERTER SUB-ASSEMBLY (w/ Exhaust Gas Temperature Sensor for EGR)
89463C
4.CONNECT NO. 1 NITROGEN OXIDES SENSOR
for Air Cooled Type Intercooler (w/ Exhaust Gas Temperature Sensor for EGR):
Attach the 5 clamps and connect the No. 1 nitrogen oxides sensor.
Install the 2 bolts.
Connect the connector to the No. 1 nitrogen oxides sensor.
for Water Cooled Type Intercooler:
|
Bolt |
|
Connector |
Attach the 6 clamps and connect the No. 1 nitrogen oxides sensor.
Install the 2 bolts.
Connect the connector to the No. 1 nitrogen oxides sensor.
55701J
5.INSTALL OUTER COWL TOP PANEL SUB-ASSEMBLY
85110
6.INSTALL WINDSHIELD WIPER MOTOR ASSEMBLY