2007-2013 Highlander Kluger · Service Manual ENGINE

P0443 Evaporative Emission Control System Purge Control Valve Circuit

Diagnostic trouble codes · Vehicles built May 2007 – Jul 2008

Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010

DESCRIPTION

To reduce hydrocarbon emissions, evaporated fuel from the fuel tank is routed through the charcoal canister to the intake manifold for combustion in the cylinders.
The ECM changes the duty signal to the purge VSV so that the intake quantity of hydrocarbon emissions is appropriate for the driving conditions (engine load, engine speed, vehicle speed, etc.) after the engine is warmed up.
DTC No.
DTC Detection Condition
Trouble Area
P0443
Proper response to ECM command does not occur
(1 trip detection logic)
  1. Open or short in purge VSV circuit
  2. Purge VSV
  3. ECM

WIRING DIAGRAM

A173976E01

INSPECTION PROCEDURE

HINT:
Read freeze frame data using the intelligent tester. Freeze frame data records the engine conditions when a malfunction is detected. When troubleshooting, freeze frame data can help determine if the vehicle was running or stopped, if the engine was warmed up or not, if the air fuel ratio was lean or rich, and other data from the time the malfunction occurred.


1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER (PURGE VSV)

  1. A142079E01
    Disconnect the vacuum hose from the purge VSV.

  1. Connect the intelligent tester to the DLC3.

  1. Start the engine and turn the tester ON.

  1. Enter the following menus: Power train / Engine / Active Test / Activate the VSV for EVAP Control. Press the right or left button.

  1. Check if air is sucked into the port when operating the purge VSV using the intelligent tester.

    OK:
    Tester Operation
    Specified Condition
    VSV is ON
    Air is sucked
    VSV is OFF
    No air sucked



NG
Go to step 2
OK

CHECK FOR INTERMITTENT PROBLEMS (Click here)

2. INSPECT TERMINAL VOLTAGE (PURGE VSV CONNECTOR)

  1. A168214E02
    Disconnect the purge VSV connector.

  1. Turn the ignition switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    1 - Body ground
    Ignition switch on (IG)
    9 to 14 V

  1. Reconnect the purge VSV connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (EFI NO. 3 FUSE - PURGE VSV)
OK


3. INSPECT PURGE VSV (OPERATION)
  1. Inspect the purge VSV operation (Click here).



NG
REPLACE PURGE VSV (Click here)
OK


4. CHECK HARNESS AND CONNECTOR (ECM - VSV FOR EVAP)

  1. A168213E03
    Disconnect the purge VSV connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Specified Condition
    B29-2 (Purge VSV) - B1-34 (PRG)
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Specified Condition
    B29-2 (Purge VSV) or B1-34 (PRG) - Body ground
    10 kΩ or higher

  1. Reconnect the ECM connector.

  1. Reconnect the purge VSV connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR (ECM - PURGE VSV)
OK

REPLACE ECM (Click here)


← P0420 Catalyst System Efficiency Below Threshold (Bank 1) (+ P0430) (from Jul 2010)P0443 Evaporative Emission Control System Purge Control Valve Circuit (Aug 2008 – Jun 2010) →