Entire Combination Meter does not Operate
Circuit diagnosis · Vehicles built from Jul 2010
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is an IG power source mainly used for signal transmission. The constant power source is mainly used as a backup power source of the meter CPU, however, it is also used for CAN communication. If a voltage of 12 V is not applied to terminal IG+ when the ignition switch is on (IG), the indicator will not operate.WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. INSPECT COMBINATION METER ASSEMBLY |
Disconnect the E1 connector.

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
E1-20 (ES) - Body ground
Always
Below 1 Ω
E1-40 (E2) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
E1-1 (IG+) - Body ground
Ignition switch on (IG)
10 to 14 V
E1-21 (B) - Body ground
Always
10 to 14 V
E1-22 (B2) - Body ground
Always
10 to 14 V
|
|
||||
| OK | ||
| ||