Enter the "Microphone&Voice Recognition Check" screen (Check Mic & Voice Recognition) (Click here).
When voice is input into the microphone, check that the microphone input level meter changes according to the input voice.
Push the recording switch and perform voice recording.
HINT:
Voice can be recorded up to 5 seconds.
Select the recording switch with the blower motor of the air conditioning system stopped. If an outlet of the air conditioning system is facing the microphone, noise may be recorded.
Check that the recording indicator remains on while recording and that the recorded voice is played normally without noise or distortion.
OK:
All check results are normal.
Text in Illustration
*a
Microphone Input Level Meter
*b
Recording Switch
*c
Stop Switch
*d
Play Switch
*e
Recording Indicator
NG
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)