2007-2013 Highlander Kluger · Service Manual TRANSMISSION

P0748 Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1)

Diagnostic trouble codes · Vehicles built May 2007 – Jul 2008

Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010

DESCRIPTION

Shifting from 1st to 5th is performed in combination with "ON" and "OFF" operation of the shift solenoid valves SL1, SL2, SL3, S4 and SR which are controlled by the ECM. If an open or short circuit occurs in either of the shift solenoid valves, the ECM controls the remaining normal shift solenoid valves to allow the vehicle to be operated smoothly (Fail safe function).
DTC No.
DTC Detection Condition
Trouble Area
P0748
The ECM checks for an open or short in the shift solenoid valve SL1 circuit while driving and shift gears.
(1-trip detection logic)
  1. Output signal duty equals to 100 %.
    (NOTE: SL1 output signal duty is less than 100 % under normal condition.)
  1. Open or short in shift solenoid valve SL1 circuit
  2. Shift solenoid valve SL1
  3. ECM

MONITOR DESCRIPTION

The ECM commands gear shifts by turning the shift solenoid valves "ON/OFF". When there is an open or short circuit in any shift solenoid valve circuit, the ECM detects the problem and illuminates the MIL and stores the DTC. And the ECM performs the fail-safe function and turns the other normal shift solenoid valves "ON/OFF" (In case of an open or short circuit, the ECM stops sending current to the circuit.) (Click here).

WIRING DIAGRAM

G031765E63

INSPECTION PROCEDURE


1. INSPECT TRANSMISSION WIRE (SL1)

  1. C113969E51
    Disconnect the transmission wire connector from the transaxle.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    6 (SL1+) - 13 (SL1-)
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    6 (SL1+) - Body ground
    Always
    10 kΩ or higher
    13 (SL1-) - Body ground
    Always
    ↑



NG
Go to step 3
OK


2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)

  1. C168530E13
    Connect the transmission wire connector to the transaxle.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    B2-19 (SL1+) - B2-18 (SL1-)
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for short):
    Tester Connection
    Condition
    Specified Condition
    B2-19 (SL1+) - Body ground
    Always
    10 kΩ or higher
    B2-18 (SL1-) - Body ground



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (for 2GR-FE) (Click here)

3. INSPECT SHIFT SOLENOID VALVE (SL1)

  1. G020767E88
    Remove the shift solenoid valve SL1.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    1 - 2
    20°C (68°F)
    5.0 to 5.6 Ω

  1. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

    OK:
    The solenoid makes an operating sound.



NG
REPLACE SHIFT SOLENOID VALVE (SL1) (Click here)
OK

REPAIR OR REPLACE TRANSMISSION WIRE (Click here)


← P0746 Pressure Control Solenoid "A" Performance (Shift Solenoid Valve SL1) (from Jul 2010)P0748 Pressure Control Solenoid "A" Electrical (Shift Solenoid Valve SL1) (Aug 2008 – Jun 2010) →