2007-2013 Highlander Kluger · Service Manual HEATER & AIR CONDITIONING SYSTEM

B1411/11 Room Temperature Sensor Circuit

Diagnostic trouble codes · Vehicles built from Jul 2010

Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010

DESCRIPTION

The room temperature sensor is installed in the instrument panel to detect the room temperature and control the heater and air conditioning AUTO mode. The resistance of the room temperature sensor changes in accordance with the room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies a voltage (5 V) to the room temperature sensor and reads voltage changes as changes in the resistance of the room temperature sensor.
DTC No.
DTC Detection Condition
Trouble Area
B1411/11
Open or short in room temperature sensor circuit
  1. Room temperature sensor (for front)
  2. Wire harness between room temperature sensor and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM

E115796E10

INSPECTION PROCEDURE


1. READ VALUE USING INTELLIGENT TESTER (ROOM TEMP)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the intelligent tester main switch on.

  1. Select the item below in the Data List, and read the value displayed on the intelligent tester.

    Data List / Air Conditioner: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    Room Temp
    Room temperature sensor /
    Min.: -6.5°C (20.3°F)
    Max.: 57.25°C (135.05°F)
    Actual room temperature is displayed
    Open circuit: -6.5°C (20.3°F)
    Short circuit: 57.25°C (135.05°F)

    OK:
    The display is as specified in the normal condition column.


    Result:
    Result
    Proceed to
    NG
    A
    OK (Checking from PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
A


2. INSPECT ROOM TEMPERATURE SENSOR

  1. E117004E18
    Remove the room temperature sensor (for front) (Click here).

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D23-1 (+) - D23-2 (-)
    10°C (50°F)
    3.00 to 3.73 kΩ
    D23-1 (+) - D23-2 (-)
    15°C (59°F)
    2.45 to 2.88 kΩ
    D23-1 (+) - D23-2 (-)
    20°C (68°F)
    1.95 to 2.30 kΩ
    D23-1 (+) - D23-2 (-)
    25°C (77°F)
    1.60 to 1.80 kΩ
    D23-1 (+) - D23-2 (-)
    30°C (86°F)
    1.28 to 1.47 kΩ
    D23-1 (+) - D23-2 (-)
    35°C (95°F)
    1.00 to 1.22 kΩ
    D23-1 (+) - D23-2 (-)
    40°C (104°F)
    0.80 to 1.00 kΩ
    D23-1 (+) - D23-2 (-)
    45°C (113°F)
    0.65 to 0.85 kΩ
    D23-1 (+) - D23-2 (-)
    50°C (122°F)
    0.50 to 0.70 kΩ
    D23-1 (+) - D23-2 (-)
    55°C (131°F)
    0.44 to 0.60 kΩ
    D23-1 (+) - D23-2 (-)
    60°C (140°F)
    0.36 to 0.50 kΩ

    NOTICE:
    1. Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
    2. When measuring, the sensor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE ROOM TEMPERATURE SENSOR (Click here)
OK


3. CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)

  1. E152696E04
    Disconnect the D23 sensor connector.

  1. Disconnect the D33 amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    D23-1 (+) - D33-29 (TR)
    Always
    Below 1 Ω
    D23-2 (-) - D33-35 (SG-4)
    Always
    Below 1 Ω
    D23-1 (+) - Body ground
    Always
    1 MΩ or higher
    D23-2 (-) - Body ground
    Always
    1 MΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER (Click here)