Skid Control ECU Communication Stop Mode
Circuit diagnosis · Vehicles built from Jul 2010
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
| Detection Item |
Symptom |
Trouble Area |
| Skid Control ECU Communication Stop Mode |
|
|
WIRING DIAGRAM


INSPECTION PROCEDURE
- NOTICE:
- Turn the ignition switch off before measuring the resistances of the CAN main wire and the CAN branch wire.
- After the ignition switch is turned off, check that the key reminder warning system and light reminder warning system are not in operation.
- Before measuring the resistance, leave the vehicle as is for at least 1 minute and do not operate the ignition switch, any other switches or the doors. If the doors need to be opened in order to check the connectors, open the doors and leave them open.
- Turn the ignition switch off before measuring the resistances of the CAN main wire and the CAN branch wire.
- HINT:
- Operating the ignition switch, any other switches, or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.
- Even after DTCs are cleared, if a DTC is stored again after driving the vehicle for a while, the malfunction may be occurring due to vibration of the vehicle. In such a case, wiggling the ECUs or wire harness while performing the inspection below will help determine the cause of the malfunction.
- Operating the ignition switch, any other switches, or a door triggers related ECU and sensor communication on the CAN. This communication will cause the resistance value to change.
| 1. CHECK CAN BUS WIRE FOR DISCONNECTION (SKID CONTROL ECU BRANCH WIRE) |
Turn the ignition switch off.
Disconnect the skid control ECU connector.
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
A24-25 (CANH) - A24-14 (CANL)
Ignition switch off
54 to 69 Ω
|
|
||||
| OK | |
| 2. CHECK HARNESS AND CONNECTOR (IG1, GND1) |
Disconnect the skid control ECU connector.
Measure the resistance according to the value(s) in the table below.

- Standard resistance:
Tester Connection
Condition
Specified Condition
A24-1 (GND1) - Body ground
Always
Below 1 Ω
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
A24-34 (IG1) - Body ground
Ignition switch on (IG)
10 to 14 V
|
|
||||
| OK | |
| 3. CHECK DTC OUTPUT |
Check the skid control ECU output DTC (Click here).
Read the DTC.
- OK:
- C1241 is not stored.
|
|
||||
| OK | ||
| ||