ON-VEHICLE INSPECTION
Inspection · Vehicles built from May 2007
| INSPECT A/C PRESSURE SENSOR |
Install the manifold gauge set.
Disconnect the connector from the A/C pressure sensor.
Connect the three 1.5 V dry cell batteries' positive (+) lead to terminal 3 and the negative (-) lead to terminal 1.

Connect the voltmeter's positive (+) lead to terminal 2 and the negative (-) lead to terminal 1.
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
Condition
Specified Condition
2 - 1
Refrigerant pressure:
0.39 to 3.187 MPa (57 to 463 psi)
1.0 to 4.8 V