C1552 PIG Power Supply Voltage Malfunction
Diagnostic trouble codes · Vehicles built from Jul 2010
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
When a problem occurs in the power steering system, the power source relay circuit is shut off to stop the power assist.
DTC No.
|
DTC Detection Condition
|
Trouble Area
|
C1552
|
PIG power source circuit malfunction inside ECU
|
- PIG power source circuit
- Power steering ECU
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (PIG POWER SUPPLY) |
 |
Turn the ignition switch off.
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Chassis / EMPS / Data List.
Select the item "PIG Power Supply" in the Data List and read the value displayed on the intelligent tester.
EMPS:
Tester Display
|
Measurement Item/Range
|
Normal Condition
|
Diagnostic Note
|
PIG Power Supply
|
PIG power supply: Min.: 0 V Max.: 20.1531 V
|
11 to 14 V
|
Power steering is in operation
|
- OK:
- The normal condition value is displayed on the intelligent tester.
|
NG |
 |
|
|
|
| OK |
|
 |
|
| CHECK INTERMITTENT PROBLEMS |
|
| 2. CHECK HARNESS AND CONNECTOR (POWER STEERING ECU - BATTERY AND BODY GROUND) |
 |
- Disconnect the connector from the power steering ECU.
Measure the voltage according to the value(s) in the table below.
- Standard voltage:
Tester Connection
|
Switch Condition
|
Specified Condition
|
D4-1 (PIG) - Body ground
|
Ignition switch on (IG)
|
11 to 14 V
|
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
|
Condition
|
Specified Condition
|
D4-2 (PGND) - Body ground
|
Always
|
Below 1 Ω
|
|
NG |
 |
|
| REPAIR OR REPLACE HARNESS OR CONNECTOR |
|
|
| OK |
|
 |
|
|