2007-2013 Highlander Kluger · Service Manual ENGINE

P0031 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1)

Diagnostic trouble codes · Vehicles built Aug 2008 – Jun 2010

Also covers:

Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010

DESCRIPTION

Refer to DTC P2195 (Click here).

HINT:
  1. Although the DTC titles say the oxygen sensor, these DTCs relate to the air fuel ratio sensor.
  2. Sensor 1 refers to the sensor mounted in front of the three-way catalytic converter and located near the engine assembly.
  3. When any of these DTCs are set, the ECM enters fail-safe mode. The ECM turns off the air fuel ratio sensor heater in fail-safe mode. Fail-safe mode continues until the ignition switch is turned off.
  4. The ECM provides a pulse width modulated control circuit to adjust the current through the heater. The air fuel ratio sensor heater circuit uses a relay on the +B side of the circuit.

A133850E10
DTC No.
DTC Detection Condition
Trouble Area
P0031
P0051
Air fuel ratio sensor heater current less than 0.8 A (1 trip detection logic)
  1. Open in air fuel ratio sensor heater circuit
  2. Air fuel ratio sensor heater
  3. Air fuel ratio sensor heater relay
  4. ECM
P0032
P0052
Air fuel ratio sensor heater current more than 10 A (1 trip detection logic)
  1. Short in air fuel ratio sensor heater circuit
  2. Air fuel ratio sensor heater
  3. Air fuel ratio sensor heater relay
  4. ECM

HINT:
  1. Bank 1 refers to the bank that includes cylinder No. 1.
  2. Bank 2 refers to the bank that does not include cylinder No. 1.
  3. Sensor 1 refers to the closest sensor to the engine assembly.
  4. Sensor 2 refers to the furthest sensor away from the engine assembly.


WIRING DIAGRAM

Refer to DTC P2195 (Click here).

INSPECTION PROCEDURE

HINT:
Read freeze frame data using the intelligent tester. The ECM records vehicle and driving condition information as freeze frame data the moment a DTC is stored. When troubleshooting, freeze frame data can be helpful in determining whether the vehicle was running or stopped, whether the engine was warmed up or not, whether the air fuel ratio was lean or rich, as well as other data recorded at the time of a malfunction.


1. INSPECT AIR FUEL RATIO SENSOR (HEATER RESISTANCE)

  1. A126269E39
    Disconnect the air fuel ratio sensor connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    B20-1 (HA1A) - B20-2 (+B)
    20°C (68°F)
    1.8 to 3.4 Ω
    B20-1 (HA1A) - B20-4 (A1A-)
    Always
    10 kΩ or higher
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    B19-1 (HA2A) - B19-2 (+B)
    20°C (68°F)
    1.8 to 3.4 Ω
    B19-1 (HA2A) - B19-4 (A2A-)
    Always
    10 kΩ or higher

  1. Reconnect the air fuel ratio sensor connector.



NG
REPLACE AIR FUEL RATIO SENSOR (Click here)
OK


2. INSPECT TERMINAL VOLTAGE (+B TERMINAL OF AIR FUEL RATIO SENSOR)

  1. A168194E01
    Disconnect the air fuel ratio sensor connector.

  1. Turn the ignition switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    B20-2 (+B) - Body ground
    Ignition switch on (IG)
    9 to 14 V
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    B19-2 (+B) - Body ground
    Ignition switch on (IG)
    9 to 14 V

  1. Reconnect the air fuel ratio sensor connector.



NG
Go to step 4
OK


3. CHECK HARNESS AND CONNECTOR (AIR FUEL RATIO SENSOR - ECM)

  1. A168195E04
    Disconnect the air fuel ratio sensor connector.

  1. Disconnect the ECM connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    B20-1 (HA1A) - B2-2 (HA1A)
    Always
    Below 1 Ω
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    B19-1 (HA2A) - B2-1 (HA2A)
    Always
    Below 1 Ω


    Standard resistance (Check for short):
    Bank 1:
    Tester Connection
    Condition
    Specified Condition
    B20-1 (HA1A) or B2-2 (HA1A) - Body ground
    Always
    10 kΩ or higher
    Bank 2:
    Tester Connection
    Condition
    Specified Condition
    B19-1 (HA2A) or B2-1 (HA2A) - Body ground
    Always
    10 kΩ or higher

  1. Reconnect the air fuel ratio sensor connector.

  1. Reconnect the ECM connector.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE ECM (Click here)

4. INSPECT FUSE (A/F FUSE)

  1. A168235E01
    Remove the A/F fuse from engine room relay block.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    A/F fuse
    Always
    Below 1 Ω

  1. Reinstall the A/F fuse.



NG
REPLACE FUSE (A/F FUSE)
OK


5. INSPECT ENGINE ROOM JUNCTION BLOCK ASSEMBLY (A/F RELAY)
  1. Inspect the A/F relay (Click here).



NG
REPLACE ENGINE ROOM JUNCTION BLOCK ASSEMBLY (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR (AIR FUEL RATIO SENSOR - A/F FUSE)


← P0031 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1) (+ P0032, P0051, P0052) (May 2007 – Jul 2008)P0031 Oxygen (A/F) Sensor Heater Control Circuit Low (Bank 1 Sensor 1) (+ 5 more codes) (from Jul 2010) →