2007-2013 Highlander Kluger · Service Manual HEATER & AIR CONDITIONING SYSTEM

B1417/17 Rear Evaporator Temperature Sensor Circuit

Diagnostic trouble codes · Vehicles built from Jul 2010

Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010

DESCRIPTION

The rear air conditioning harness (rear evaporator temperature sensor) is installed on the evaporator in the rear air conditioning unit to detect the temperature of the cooled air that has passed through the evaporator and to control the rear air conditioner. It sends signals to the air conditioning amplifier. The signals change in accordance with the resistance of the rear air conditioning harness (rear evaporator temperature sensor). As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases. The air conditioning amplifier applies a voltage (5 V) to the rear air conditioning harness (rear evaporator temperature sensor) and reads voltage changes as changes in the resistance of the rear air conditioning harness (rear evaporator temperature sensor). This sensor is used for frost prevention.
DTC No.
DTC Detection Condition
Trouble Area
B1417/17
Open or short in rear air conditioning harness circuit (rear evaporator temperature sensor)
  1. Rear air conditioning harness (rear evaporator temperature sensor)
  2. Wire harness between rear air conditioning harness (rear evaporator temperature sensor) and air conditioning amplifier
  3. Air conditioning amplifier

WIRING DIAGRAM

E127591E04

INSPECTION PROCEDURE


1. READ VALUE USING INTELLIGENT TESTER (R-EVAP TEMP SEN)
  1. Connect the intelligent tester to the DLC3.

  1. Turn the ignition switch on (IG) and turn the intelligent tester main switch on.

  1. Select the item below in the Data List, and read the value displayed on the intelligent tester.

    Data List / Air Conditioner: 
    Tester Display
    Measurement Item/Range
    Normal Condition
    Diagnostic Note
    R-Evap Temp Sen
    Rear evaporator temperature sensor /
    Min.: -29.7°C (-21.46°F)
    Max.: 59.55°C (139.19°F)
    Actual rear evaporator temperature is displayed
    Open circuit: -29.7°C (-21.46°F)
    Short circuit: 59.55°C (139.19°F)

    OK:
    The display is as specified in the normal condition column.


    Result:
    Result
    Proceed to
    NG
    A
    OK (Checking from PROBLEM SYMPTOMS TABLE)
    B
    OK (Checking from DTC)
    C



B
PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE (Click here)

C
REPLACE AIR CONDITIONING AMPLIFIER (Click here)
A


2. INSPECT REAR AIR CONDITIONING HARNESS (REAR EVAPORATOR TEMPERATURE SENSOR)

  1. E127592E14
    Remove the rear air conditioning harness.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    N11-7 (-) - N11-8 (+)
    -10°C (14°F)
    7.30 to 9.10 kΩ
    N11-7 (-) - N11-8 (+)
    -5°C (23°F)
    5.65 to 6.95 kΩ
    N11-7 (-) - N11-8 (+)
    0°C (32°F)
    4.40 to 5.35 kΩ
    N11-7 (-) - N11-8 (+)
    5°C (41°F)
    3.40 to 4.15 kΩ
    N11-7 (-) - N11-8 (+)
    10°C (50°F)
    2.70 to 3.25 kΩ
    N11-7 (-) - N11-8 (+)
    15°C (59°F)
    2.14 to 2.58 kΩ
    N11-7 (-) - N11-8 (+)
    20°C (68°F)
    1.71 to 2.05 kΩ
    N11-7 (-) - N11-8 (+)
    25°C (77°F)
    1.38 to 1.64 kΩ
    N11-7 (-) - N11-8 (+)
    30°C (86°F)
    1.11 to 1.32 kΩ

    NOTICE:
    1. Touching the thermistor even slightly may change the resistance value. Be sure to hold the connector of the thermistor.
    2. When measuring, the thermistor temperature must be the same as the ambient temperature.

    HINT:
    As the temperature increases, the resistance decreases (see the graph).



NG
REPLACE REAR AIR CONDITIONING HARNESS
OK


3. CHECK HARNESS AND CONNECTOR (REAR AIR CONDITIONING HARNESS - AIR CONDITIONING AMPLIFIER)

  1. E153085E07
    Disconnect the N11 rear air conditioning harness connector.

  1. Disconnect the D34 amplifier connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    N11-8 (+) - D34-4 (TEC)
    Always
    Below 1 Ω
    N11-7 (-) - D34-19 (SGND)
    Always
    Below 1 Ω



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

REPLACE AIR CONDITIONING AMPLIFIER (Click here)


← B1417/17 Rear Evaporator Temperature Sensor Circuit (Aug 2008 – Jun 2010)B1422/22 Compressor Lock Sensor Circuit (May 2007 – Jul 2008) →