B1419/19 Rear Room Temperature Sensor Circuit
Diagnostic trouble codes · Vehicles built from Jul 2010
Versions by build date: May 2007 – Jul 2008 Aug 2008 – Jun 2010 from Jul 2010
DESCRIPTION
The rear room temperature sensor is installed in the rear panel to detect the rear room temperature and control the heater and air conditioning AUTO mode. The resistance of the rear room temperature sensor changes in accordance with the rear room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.The air conditioning amplifier applies a voltage (5 V) to the rear room temperature sensor and reads voltage changes as changes in the resistance of the rear room temperature sensor.
| DTC No. |
DTC Detection Condition |
Trouble Area |
| B1419/19 |
Open or short in rear room temperature sensor circuit |
|
WIRING DIAGRAM


INSPECTION PROCEDURE
| 1. READ VALUE USING INTELLIGENT TESTER (REAR ROOM TEMP) |
Connect the intelligent tester to the DLC3.
Turn the ignition switch on (IG) and turn the intelligent tester main switch on.
Select the item below in the Data List, and read the value displayed on the intelligent tester.
Data List / Air Conditioner: Tester Display
Measurement Item/Range
Normal Condition
Diagnostic Note
Rear room Temp
Rear room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual rear room temperature is displayed
Open circuit: -6.5°C (20.3°F)
Short circuit: 57.25°C (135.05°F)
- OK:
- The display is as specified in the normal condition column.
- Result:
Result
Proceed to
NG
A
OK (Checking from the PROBLEM SYMPTOMS TABLE)
B
OK (Checking from the DTC)
C
|
|
||||
|
|
||||
| A | |
| 2. INSPECT REAR ROOM TEMPERATURE SENSOR |
Remove the rear room temperature sensor (Click here).

Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
N12-1 (+) - N12-2 (-)
10°C (50°F)
3.00 to 3.73 kΩ
N12-1 (+) - N12-2 (-)
15°C (59°F)
2.45 to 2.88 kΩ
N12-1 (+) - N12-2 (-)
20°C (68°F)
1.95 to 2.30 kΩ
N12-1 (+) - N12-2 (-)
25°C (77°F)
1.60 to 1.80 kΩ
N12-1 (+) - N12-2 (-)
30°C (86°F)
1.28 to 1.47 kΩ
N12-1 (+) - N12-2 (-)
35°C (95°F)
1.00 to 1.22 kΩ
N12-1 (+) - N12-2 (-)
40°C (104°F)
0.80 to 1.00 kΩ
N12-1 (+) - N12-2 (-)
45°C (113°F)
0.65 to 0.85 kΩ
N12-1 (+) - N12-2 (-)
50°C (122°F)
0.50 to 0.70 kΩ
N12-1 (+) - N12-2 (-)
55°C (131°F)
0.44 to 0.60 kΩ
N12-1 (+) - N12-2 (-)
60°C (140°F)
0.36 to 0.50 kΩ
- NOTICE:
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- When measuring, the sensor temperature must be the same as the ambient temperature.
- Touching the sensor even slightly may change the resistance value. Be sure to hold the connector of the sensor.
- HINT:
- As the temperature increases, the resistance decreases (see the graph).
|
|
||||
| OK | |
| 3. CHECK HARNESS AND CONNECTOR (REAR ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER) |
Disconnect the N12 sensor connector.

Disconnect the D34 amplifier connector.
Measure the resistance according to the value(s) in the table below.
- Standard resistance:
Tester Connection
Condition
Specified Condition
N12-1 - D34-17 (TR)
Always
Below 1 Ω
N12-2 - D34-7 (SG-6)
Always
Below 1 Ω
N12-1 - Body ground
Always
1 MΩ or higher
N12-2 - Body ground
Always
1 MΩ or higher
|
|
||||
| OK | ||
| ||
