DTC B2271 Ignition Hold Monitor Malfunction |
| DTC No. | DTC Detection Condition | Trouble Area |
| B2271 | Hold circuit, IG1 relay actuation circuit or IG2 relay actuation circuit inside main body ECU (instrument panel junction block) is open or shorted |
|

| 1.CHECK DTC OUTPUT |
Delete the DTCs (Click here).
Check for DTCs again.
|
| ||||
| OK | ||
| ||
| 2.CHECK HARNESS AND CONNECTOR (MAIN BODY ECU (INSTRUMENT PANEL JUNCTION BLOCK) - BATTERY) |
![]() |
Disconnect the D7 and D8 ECU connectors.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| D8-6 (AM1) - Body ground | Always | 11 to 14 V |
| D7-1 (AM2) - Body ground | Always | 11 to 14 V |
|
| ||||
| OK | ||
| ||