DTC P0A82-123 Hybrid Battery Pack Cooling Fan 1 |
| DTC No. | DTC Detection Condition | Trouble Area |
| P0A82-123 | Speed of the battery cooling blower assembly is not within the specified range (1 trip detection) |
|
| 1.CHECK DTC OUTPUT (DTC P0A1F-123 IS OUTPUT) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs (Click here).
| Result | Proceed to |
| P0A82-123 only is output | A |
| P0A1F-123 is output | B |
| Any of P0A84-123, P0A85-123, P0A99-123, P0A9A-123, P0AD2-123, and P0AD3-123 are output | C |
|
| ||||
|
| ||||
| A | |
| 2.CHECK BATTERY COOLING BLOWER ASSEMBLY |
Connect the Techstream to the DLC3.
Select the following menu items: Powertrain / Hybrid Control / Data List / VMF Fan Motor Voltage 1 to 3 and Temp of BATT TB 1 to 8.
Perform a road test and check that there is a malfunction in the VMF Fan Motor Voltage 1 while the battery cooling blower assembly is operating. (*1)
![]() |
Remove the battery cover and replace the battery cooling blower assembly with another battery cooling blower assembly (Click here).
Install the battery cover.
Select the following menu items: Powertrain / Hybrid Control / Data List / VMF Fan Motor Voltage 1 to 3 and Temp of BATT TB 1 to 8.
Perform a road test and check that a malfunction in (*1) is reproduced in another battery cooling blower assembly.
| Result | Proceed to |
| The malfunction is reproduced in the same battery cooling blower. | A |
| The malfunction is reproduced in another battery cooling blower. | B |
|
| ||||
| A | |
| 3.CHECK HARNESS AND CONNECTOR (BATTERY SMART UNIT - BATTERY COOLING BLOWER ASSEMBLY) |
Remove the service plug grip.
Remove the battery cover.
![]() |
Disconnect the O45 connector from the battery cooling blower assembly.
Disconnect the z18 connector from the battery smart unit (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O45-2 (VM0) - z18-3 (VM0) | Power switch off | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - BATTERY COOLING BLOWER ASSEMBLY) |
Disconnect D36 connector from the hybrid vehicle control ECU (Click here).
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| O45-3 (Sl0) - D36-15 (Sl0) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| O45-3 (Sl0) - O45-4 (GND0) | Power switch off | 10 kΩ or more |
| O45-3 (Sl0) - Body ground | Power switch off | 10 kΩ or more |
|
| ||||
| OK | |
| 5.READ VALUE USING TECHSTREAM |
Connect the O45, z18 and D36 connector.
Connect the Techstream to the DLC3.
Turn the power switch on (IG) and the Techstream on.
Select the following menu items: Powertrain / Hybrid Control / Active Test / Driving the Battery Cooling Fan.
Select the following menu items: All Data / VMF Fan Motor Voltage 1.
Select each air volume mode (1 to 6) in the "Driving the Battery Cooling Fan" active test to operate the battery cooling blower assembly.
![]() |
While the cooling fan is operating, compare the value in the Data List (VMF Fan Motor Voltage 1) with the voltage value that was actually measured at the battery cooling blower assembly connector.
| Tester Connection | Condition | Specified Condition |
| O45-2 (VM0) - O45-4 (GND0) | Battery cooling blower is operating | Difference between the value in the Data List (VMF Fan Motor Voltage 1) and the actual measurement value is 1 V or less. |
|
| ||||
| OK | ||
| ||