Home › HYBRID SYSTEM · P310 › HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

DTC    U0110-159    Lost Communication with Driver Motor Control Module

DTC    U0110-656    Lost Communication with Driver Motor Control Module

DTC    U0110-657    Lost Communication with Driver Motor Control Module

for Preparation Click here


DESCRIPTION

Refer to the description of the inverter with converter assembly .
The inverter with converter assembly (MG ECU) controls MG2 based on commands from the hybrid vehicle control ECU via serial communication.
The inverter with converter assembly (MG ECU) monitors communication data and detects a malfunction.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
U0110
159
Error in reception from inverter with converter assembly (MG ECU) via serial communication (out of communication standard)
  1. Wire harness or connector
  2. Inverter with converter assembly (MG ECU)
  3. Hybrid vehicle control ECU
  4. IGCT NO. 2 fuse
656
Error in reception from inverter with converter assembly (MG ECU) via serial communication (out of communication standard)
657
Error in reception from inverter with converter assembly (MG ECU) via serial communication (no reception)

WIRING DIAGRAM


A178010E02


INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals. After waiting for 5 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

NOTICE:
If any of the DTCs U0110-159, U0110-656, and U0110-657 was set due to incomplete engagement of the connectors, and if the system returns to normal when the power switch is turned on (IG) after clearing the DTCs, DTC P0A1B-788 (power source IC reset) will be set. Proceed to troubleshooting without considering DTC P0A1B-788.

HINT:
Waiting for at least 5 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

1.CHECK FUSE (IGCT NO. 2)


    A174903E03
  1. Check if there is an open circuit in the fuse (IGCT NO. 2) in the No. 2 engine room relay block.

    OK:
    There is no open circuit in the fuse (IGCT NO. 2).



NG
Go to step 14
OK


2.CHECK HYBRID VEHICLE CONTROL ECU (CHECK WAVEFORM)


    A175154E02
  1. Connect an oscilloscope between the hybrid vehicle control ECU terminals specified in the following table, and measure the waveform.
    Item
    Contents
    Terminal
    A43-22 (CLK+) - B3-5 (E1)
    A43-29 (CLK-) - B3-5 (E1)
    Equipment Setting
    1 V/DIV, 1 μs/DIV
    Condition
    Power switch on (READY)

    Result:
    Result
    Proceed to
    The waveform appears as shown in the illustration.
    A
    The waveform differs from the one shown in the illustration.
    B

    HINT:
    The shape of the waveform may vary according to communication conditions.



B
Go to step 5
A


3.CHECK HYBRID VEHICLE CONTROL ECU (CHECK WAVEFORM)


    A175155E03
  1. Connect an oscilloscope between the hybrid vehicle control ECU terminals specified in the following table, and measure the waveform.
    Item
    Contents
    Terminal
    A43-23 (REQ+) - B3-5 (E1)
    A43-30 (REQ-) - B3-5 (E1)
    Equipment Setting
    1 V/DIV, 1 ms/DIV
    Condition
    Power switch on (READY)

    Result:
    Result
    Proceed to
    The waveform appears as shown in the illustration.
    A
    The waveform differs from the one shown in the illustration.
    B

    HINT:
    The shape of the waveform may vary according to communication conditions.



B
Go to step 8
A


4.CHECK HYBRID VEHICLE CONTROL ECU (CHECK WAVEFORM)


    A175153E03
  1. Connect an oscilloscope between the hybrid vehicle control ECU terminals specified in the following table, and measure the waveform.
    Item
    Contents
    Terminal
    A43-28 (MTH+) - B3-5 (E1)
    A43-27 (MTH-) - B3-5 (E1)
    Equipment Setting
    1 V/DIV, 200 μs/DIV
    Condition
    Power switch on (READY)

    Result:
    Result
    Proceed to
    The waveform appears as shown in the illustration.
    A
    The waveform differs from the one shown in the illustration.
    B

    HINT:
    The shape of the waveform may vary according to communication conditions.



B
Go to step 11
A

REPLACE HYBRID VEHICLE CONTROL ECU (Click here)  

5.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - MG ECU)

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the power switch off.

  1. Remove the service plug grip (Click here).

  1. Disconnect connector A43 from the hybrid vehicle control ECU.

  1. Remove the inverter cover (Click here).

    NOTICE:
    1. Wrap the round interlock terminal for the inverter cover with insulating tape to prevent it from shorting to ground.
    2. Be sure to prevent coolant in the inverter reserve tank from entering the inverter.
    3. Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.

  1. Disconnect connector A42 from the MG ECU.

  1. Turn the power switch on (IG).



    A175145E09
  1. Measure the voltage according to the value(s) in the table below.

    HINT:
    Turning the power switch on (IG) with the service plug grip and inverter cover removed causes an interlock switch system DTC (P0A0D-350) to be set.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A43-22 (CLK+) - Body ground
    Power switch on (IG)
    Below 1 V
    A43-29 (CLK-) - Body ground
    Power switch on (IG)
    Below 1 V

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Switch Condition
    Specified Condition
    A43-22 (CLK+) - A42-17 (CLK+)
    Power switch off
    Below 1 Ω
    A43-29 (CLK-) - A42-18 (CLK-)
    Power switch off
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Switch Condition
    Specified Condition
    A43-22 (CLK+) or A42-17 (CLK+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A43-29 (CLK-) or A42-18 (CLK-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


6.CHECK INVERTER WITH CONVERTER ASSEMBLY
  1. Connect connector A42 to the MG ECU.



    A175539E06
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A43-22 (CLK+) - A43-29 (CLK-)
    Power switch off
    115 to 130 Ω



NG
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
OK


7.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY)
  1. Turn the power switch on (IG).



    A174426E08
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A42-7 (+B) - Body ground
    Power switch on (IG)
    11 to 14 V
    A42-4 (+B2) - Body ground
    Power switch on (IG)
    11 to 14 V

    HINT:
    Turning the power switch on (IG) with the service plug grip and inverter cover removed causes an interlock switch system DTC (P0A0D-350) to be set.



NG
REPAIR POWER SOURCE CIRCUIT
OK

REPLACE HYBRID VEHICLE CONTROL ECU (Click here)  

8.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - MG ECU)

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the power switch off.

  1. Remove the service plug grip (Click here).

  1. Disconnect connector A43 from the hybrid vehicle control ECU.

  1. Remove the inverter cover (Click here).

    NOTICE:
    1. Wrap the round interlock terminal for the inverter cover with insulating tape to prevent it from shorting to ground.
    2. Be sure to prevent coolant in the inverter reserve tank from entering the inverter.
    3. Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.

  1. Disconnect connector A42 from the MG ECU.

  1. Turn the power switch on (IG).



    A175145E10
  1. Measure the voltage according to the value(s) in the table below.

    HINT:
    Turning the power switch on (IG) with the service plug grip and inverter cover removed causes an interlock switch system DTC (P0A0D-350) to be set.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A43-23 (REQ+) - Body ground
    Power switch on (IG)
    Below 1 V
    A43-30 (REQ-) - Body ground
    Power switch on (IG)
    Below 1 V

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Switch Condition
    Specified Condition
    A43-23 (REQ+) - A42-15 (REQ+)
    Power switch off
    Below 1 Ω
    A43-30 (REQ-) - A42-16 (REQ-)
    Power switch off
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Switch Condition
    Specified Condition
    A43-23 (REQ+) or A42-15 (REQ+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A43-30 (REQ-) or A42-16 (REQ-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


9.CHECK INVERTER WITH CONVERTER ASSEMBLY
  1. Connect connector A42 to the MG ECU.



    A175539E07
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A43-23 (REQ+) - A43-30 (REQ-)
    Power switch off
    115 to 130 Ω



NG
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
OK


10.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY)
  1. Turn the power switch on (IG).



    A174426E09
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A42-7 (+B) - Body ground
    Power switch on (IG)
    11 to 14 V
    A42-4 (+B2) - Body ground
    Power switch on (IG)
    11 to 14 V

    HINT:
    Turning the power switch on (IG) with the service plug grip and inverter cover removed causes an interlock switch system DTC (P0A0D-350) to be set.



NG
REPAIR POWER SOURCE CIRCUIT
OK

REPLACE HYBRID VEHICLE CONTROL ECU (Click here)  

11.CHECK HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - MG ECU)

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the power switch off.

  1. Remove the service plug grip (Click here).

  1. Disconnect connector A43 from the hybrid vehicle control ECU.

  1. Remove the inverter cover (Click here).

    NOTICE:
    1. Wrap the round interlock terminal for the inverter cover with insulating tape to prevent it from shorting to ground.
    2. Be sure to prevent coolant in the inverter reserve tank from entering the inverter.
    3. Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.

  1. Disconnect connector A42 from the MG ECU.

  1. Turn the power switch on (IG).



    A175145E11
  1. Measure the voltage according to the value(s) in the table below.

    HINT:
    Turning the power switch on (IG) with the service plug grip and inverter cover removed causes an interlock switch system DTC (P0A0D-350) to be set.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A43-28 (MTH+) - Body ground
    Power switch on (IG)
    Below 1 V
    A43-27 (MTH-) - Body ground
    Power switch on (IG)
    Below 1 V

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Switch Condition
    Specified Condition
    A43-28 (MTH+) - A42-9 (MTH+)
    Power switch off
    Below 1 Ω
    A43-27 (MTH-) - A42-10 (MTH-)
    Power switch off
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Switch Condition
    Specified Condition
    A43-28 (MTH+) or A42-9 (MTH+) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    A43-27 (MTH-) or A42-10 (MTH-) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK


12.CHECK INVERTER WITH CONVERTER ASSEMBLY
  1. Connect connector A42 to the MG ECU.



    A175539E08
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    A43-28 (MTH+) - A43-27 (MTH-)
    Power switch off
    111 to 129 Ω



NG
REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)
OK


13.CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY)
  1. Turn the power switch on (IG).



    A174426E10
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    A42-7 (+B) - Body ground
    Power switch on (IG)
    11 to 14 V
    A42-4 (+B2) - Body ground
    Power switch on (IG)
    11 to 14 V

    HINT:
    Turning the power switch on (IG) with the service plug grip and inverter cover removed causes an interlock switch system DTC (P0A0D-350) to be set.



NG
REPAIR POWER SOURCE CIRCUIT
OK

REPLACE HYBRID VEHICLE CONTROL ECU (Click here)  

14.REPLACE FUSE (IGCT NO. 2)


    A174903E04
  1. Replace the fuse (IGCT NO. 2) in the No. 2 engine room relay block.

  1. Turn the power switch on (READY).

  1. Check if there is an open circuit in the fuse (IGCT NO. 2) in the No. 2 engine room relay block.

    OK:
    There is no open circuit in the fuse (IGCT NO. 2).

    HINT:
    1. If no open circuit in the fuse (IGCT NO. 2) is found after turning the power switch on (READY), there was a long-term deterioration.
    2. If there is an open circuit in the fuse (IGCT NO. 2), replace the fuse.



NG
REPAIR OR REPLACE HARNESS OR CONNECTOR
OK

END