DTC P0A1A-200 Generator Control Module |
DTC P0A1A-792 Generator Control Module |
DTC P0A1A-793 Generator Control Module |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A1A | 200 | R/D resolver angle error |
|
| 792 | REF frequency error | ||
| 793 | REF signal stop error |
| Related DTCs | P0A1A (INF 200): RD Converter Resolver angle abnormality P0A1A (INF 792): REF malfunction (REF frequency abnormality) P0A1A (INF 793): REF malfunction (REF Signal abnormality) |
| Required sensors / components | Motor Generator control ECU (MG ECU) |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | 1 driving cycle |
| Sequence of operation | None |
| The monitor will run whenever the DTCs listed are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| Motor Generator control ECU (MG ECU) | Internal error |
| Motor Generator control ECU (MG ECU) | DTC P0A1A (INF 200/792/793) is not detected |

| 1.CHECK DTC OUTPUT (HV) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A1A-200, 792, or 793 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
|
| ||||
| A | |
| 2.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR) |
Turn the power switch off.
Remove the service plug grip (Click here).
Remove the inverter cover (Click here).
![]() |
Check the connections of the MG ECU connectors.
|
| ||||
| OK | |
| 3.CHECK HARNESS AND CONNECTOR (MG ECU - GENERATOR RESOLVER) |
![]() |
Disconnect the B49 connector from the MG ECU.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-12 (GRF) - Body ground | Power switch on (IG) | Below 1 V |
| B49-22 (GRFG) - Body ground | Power switch on (IG) | Below 1 V |
| B49-11 (GSN) - Body ground | Power switch on (IG) | Below 1 V |
| B49-10 (GSNG) - Body ground | Power switch on (IG) | Below 1 V |
| B49-9 (GCS) - Body ground | Power switch on (IG) | Below 1 V |
| B49-8 (GCSG) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-12 (GRF) - B49-22 (GRFG) | Power switch off | 7.65 to 10.2 Ω |
| B49-11 (GSN) - B49-10 (GSNG) | Power switch off | 12.6 to 16.8 Ω |
| B49-9 (GCS) - B49-8 (GCSG) | Power switch off | 12.6 to 16.8 Ω |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-12 (GRF) or B49-22 (GRFG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| B49-11 (GSN) or B49-10 (GSNG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| B49-9 (GCS) or B49-8 (GCSG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | |
| 4.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Remove the inverter with converter assembly (Click here).
Check the connection of the generator resolver connector.
|
| ||||
| OK | ||
| ||
| 5.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Remove the inverter with converter assembly (Click here).
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 6.CHECK GENERATOR RESOLVER |
![]() |
Disconnect the B53 generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B53-1 (GRF) - B53-6 (GRFG) | Power switch off | 7.65 to 10.2 Ω |
| B53-2 (GSN) - B53-7 (GSNG) | Power switch off | 12.6 to 16.8 Ω |
| B53-3 (GCS) - B53-8 (GCSG) | Power switch off | 12.6 to 16.8 Ω |
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B53-1 (GRF) - B53-2 (GSN) | Power switch off | 10 MΩ or higher |
| B53-1 (GRF) - B53-3 (GCS) | Power switch off | 10 MΩ or higher |
| B53-2 (GSN) - B53-3 (GCS) | Power switch off | 10 MΩ or higher |
| B53-6 (GRFG) - B53-7 (GSNG) | Power switch off | 10 MΩ or higher |
| B53-6 (GRFG) - B53-8 (GCSG) | Power switch off | 10 MΩ or higher |
| B53-7 (GSNG) - B53-8 (GCSG) | Power switch off | 10 MΩ or higher |
| Each terminal listed above - Transaxle housing | Power switch off | 10 MΩ or higher |
|
| ||||
| OK | ||
| ||