DTC P0A4B-253 Generator Position Sensor Circuit |
DTC P0A4C-513 Generator Position Sensor Circuit Range / Performance |
DTC P0A4D-255 Generator Position Sensor Circuit Low |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A4B | 253 | Interphase short in generator resolver circuit |
|
| P0A4C | 513 | Generator resolver output is out of normal range | |
| P0A4D | 255 | Open or short in generator resolver circuit |
| Related DTCs | P0A4B (INF 253): Generator position sensor circuit malfunction / Short circuit between phases P0A4C (INF 513): Generator position sensor circuit malfunction / Range check P0A4D (INF 255): Generator position sensor circuit malfunction / open or short circuit |
| Required sensors / components | Generator resolver |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the DTCs listed are not present | TMC's intellectual property |
| Generator resolver | Circuit malfunction (interphase short, open or short), or abnormal output |
| Generator resolver | DTC P0A4B (INF 253), P0A4C (INF 513) or P0A4D (INF 255) is not detected |

| 1.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR) |
Turn the power switch off.
Remove the service plug grip (Click here).
Remove the inverter cover (Click here).
![]() |
Check the connections of the MG ECU connectors.
|
| ||||
| OK | |
| 2.INSPECT GENERATOR RESOLVER |
![]() |
Disconnect the B49 connector from the MG ECU.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-12 (GRF) - Body ground | Power switch on (IG) | Below 1 V |
| B49-22 (GRFG) - Body ground | Power switch on (IG) | Below 1 V |
| B49-11 (GSN) - Body ground | Power switch on (IG) | Below 1 V |
| B49-10 (GSNG) - Body ground | Power switch on (IG) | Below 1 V |
| B49-9 (GCS) - Body ground | Power switch on (IG) | Below 1 V |
| B49-8 (GCSG) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B49-12 (GRF) - B49-22 (GRFG) | Power switch off | 7.65 to 10.2 Ω |
| B49-11 (GSN) - B49-10 (GSNG) | Power switch off | 12.6 to 16.8 Ω |
| B49-9 (GCS) - B49-8 (GCSG) | Power switch off | 12.6 to 16.8 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| B49-12 (GRF) or B49-22 (GRFG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| B49-11(GSN ) or B49-10 (GSNG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
| B49-9 (GCS) or B49-8 (GCSG) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Remove the inverter with converter assembly (Click here).
Check the connection of the generator resolver connector.
|
| ||||
| OK | ||
| ||
| 4.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR) |
![]() |
Remove the inverter with converter assembly (Click here).
Check the connection of the generator resolver connector.
|
| ||||
| OK | |
| 5.CHECK GENERATOR RESOLVER |
![]() |
Disconnect the B53 generator resolver connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B53-1 (GRF) - B53-6 (GRFG) | Power switch off | 7.65 to 10.2 Ω |
| B53-2 (GSN) - B53-7 (GSNG) | Power switch off | 12.6 to 16.8 Ω |
| B53-3 (GCS) - B53-8 (GCSG) | Power switch off | 12.6 to 16.8 Ω |
Using a megohmmeter, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| B53-1 (GRF) - B53-2 (GSN) | Power switch off | 10 MΩ or higher |
| B53-1 (GRF) - B53-3 (GCS) | Power switch off | 10 MΩ or higher |
| B53-2 (GSN) - B53-3 (GCS) | Power switch off | 10 MΩ or higher |
| B53-6 (GRFG) - B53-7 (GSNG) | Power switch off | 10 MΩ or higher |
| B53-6 (GRFG) - B53-8 (GCSG) | Power switch off | 10 MΩ or higher |
| B53-7 (GSNG) - B53-8 (GCSG) | Power switch off | 10 MΩ or higher |
| Each terminal listed above - Transaxle housing | Power switch off | 10 MΩ or higher |
|
| ||||
| OK | ||
| ||