DTC    P0A4B-253    Generator Position Sensor Circuit

DTC    P0A4C-513    Generator Position Sensor Circuit Range / Performance

DTC    P0A4D-255    Generator Position Sensor Circuit Low

for Preparation Click here


DESCRIPTION

A resolver is a sensor that is used to detect the position of the magnetic poles of a motor rotor. Knowing the position of the poles is indispensable for ensuring precise control of a motor generator.
The resolver structure and method of connection with the MG ECU are the same as those of the motor resolver .
The MG ECU monitors output signals from the resolver and detects a malfunction.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A4B
253
Interphase short in generator resolver circuit
  1. Wire harness or connector
  2. Hybrid vehicle transaxle assembly (Generator resolver)
  3. Inverter with converter assembly (MG ECU)
P0A4C
513
Generator resolver output is out of normal range
P0A4D
255
Open or short in generator resolver circuit

MONITOR DESCRIPTION

The MG ECU monitors the generator resolver output signal. If the MG ECU detects output signals that are out of the normal range or specification, it will conclude that there is a malfunction of the generator resolver. The hybrid vehicle control ECU will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A4B (INF 253): Generator position sensor circuit malfunction / Short circuit between phases
P0A4C (INF 513): Generator position sensor circuit malfunction / Range check
P0A4D (INF 255): Generator position sensor circuit malfunction / open or short circuit
Required sensors / components
Generator resolver
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the DTCs listed are not present
TMC's intellectual property

TYPICAL MALFUNCTION THRESHOLDS


Generator resolver
Circuit malfunction (interphase short, open or short), or abnormal output

COMPONENT OPERATING RANGE


Generator resolver
DTC P0A4B (INF 253), P0A4C (INF 513) or P0A4D (INF 255) is not detected

WIRING DIAGRAM


A174402E11


INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals. After waiting for 5 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

NOTICE:
Check the output DTCs again after the repair has been completed. If P0A78-286, P0A7A-324, or P0A79-696 is output, replace the inverter with converter assembly.

HINT:
  1. Waiting for at least 5 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
  2. If the problem symptom cannot be reproduced, performing the driving test on a road on which the vehicle tends to vibrate will make it easier to reproduce the symptom.
  3. If INF code 253 is output, there may be an interphase short in the resolver circuit due to an intrusion of water into the resolver. Therefore, if the problem symptom cannot be reproduced, replace the hybrid vehicle transaxle assembly.

1.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the power switch off.

  1. Remove the service plug grip (Click here).

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the inverter cover (Click here).

    NOTICE:
    1. Wrap the round interlock terminal for the inverter cover with insulating tape to prevent it from shorting to ground.
    2. Be sure to prevent coolant in the inverter reserve tank from entering the inverter.
    3. Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.



    A170989E01
  1. Check the connections of the MG ECU connectors.

    OK:
    The connectors are connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


2.INSPECT GENERATOR RESOLVER

NOTICE:
Be sure to wear insulated gloves.



    A174438E03
  1. Disconnect the B49 connector from the MG ECU.

  1. Turn the power switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-12 (GRF) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-22 (GRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-11 (GSN) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-10 (GSNG) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-9 (GCS) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-8 (GCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    NOTICE:
    Turning the power switch on (IG) with the MG ECU connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing the inspection.

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Switch Condition
    Specified Condition
    B49-12 (GRF) - B49-22 (GRFG)
    Power switch off
    7.65 to 10.2 Ω
    B49-11 (GSN) - B49-10 (GSNG)
    Power switch off
    12.6 to 16.8 Ω
    B49-9 (GCS) - B49-8 (GCSG)
    Power switch off
    12.6 to 16.8 Ω

    Standard resistance (Check for short):
    Tester Connection
    Switch Condition
    Specified Condition
    B49-12 (GRF) or B49-22 (GRFG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    B49-11(GSN ) or B49-10 (GSNG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    B49-9 (GCS) or B49-8 (GCSG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
Go to step 4
OK


3.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A174889
  1. Remove the inverter with converter assembly (Click here).

  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

4.CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    A174889
  1. Remove the inverter with converter assembly (Click here).

  1. Check the connection of the generator resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


5.CHECK GENERATOR RESOLVER


    A174439E03
  1. Disconnect the B53 generator resolver connector.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B53-1 (GRF) - B53-6 (GRFG)
    Power switch off
    7.65 to 10.2 Ω
    B53-2 (GSN) - B53-7 (GSNG)
    Power switch off
    12.6 to 16.8 Ω
    B53-3 (GCS) - B53-8 (GCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Using a megohmmeter, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B53-1 (GRF) - B53-2 (GSN)
    Power switch off
    10 MΩ or higher
    B53-1 (GRF) - B53-3 (GCS)
    Power switch off
    10 MΩ or higher
    B53-2 (GSN) - B53-3 (GCS)
    Power switch off
    10 MΩ or higher
    B53-6 (GRFG) - B53-7 (GSNG)
    Power switch off
    10 MΩ or higher
    B53-6 (GRFG) - B53-8 (GCSG)
    Power switch off
    10 MΩ or higher
    B53-7 (GSNG) - B53-8 (GCSG)
    Power switch off
    10 MΩ or higher
    Each terminal listed above - Transaxle housing
    Power switch off
    10 MΩ or higher



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR