DTC P0A78-306 Drive Motor "A" Inverter Performance |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A78 | 306 | Malfunction in monitoring MG2 torque performance |
|
| Related DTCs | P0A78 (INF 306): Discrepancy between monitored torque and commanded torque of MG2 |
| Required sensors / components | Motor inverter |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the DTCs listed are not present | TMC's intellectual property |
| TMC's intellectual property | - |
| Motor inverter | DTC P0A78 (INF 306) is not detected |
| 1.CHECK DTC OUTPUT (HV) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A78-306 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A1A (all INF codes) *1 | Generator Control Module |
| P0A1B (all INF codes) *1 | Drive Motor "A" Control Module |
| P0A1C (all INF codes) *1 | Drive Motor "B" Control Module |
| P0A1D (all INF codes) *1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A45-669 | Drive Motor "B" Position Sensor Circuit |
| P0A46-671 | Drive Motor "B" Position Sensor Circuit Range / Performance |
| P0A47-670 | Drive Motor "B" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A51-174 | Drive Motor "A" Current Sensor Circuit |
| P0A55-687 | Drive Motor "B" Current Sensor Circuit |
| P0A60 (all INF codes) *1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes) *1 | Drive Motor "A" Phase W Current |
| P0A69 (all INF codes) *1 | Drive Motor "B" Phase V Current |
| P0A6C (all INF codes) *1 | Drive Motor "B" Phase W Current |
| P0A72 (all INF codes) *1 | Generator Phase V Current |
| P0A75 (all INF codes) *1 | Generator Phase W Current |
| P0A78-266, 267, 272, 278, 280, 283, 285, 304, 305, 508, 510, 523, 586 | Drive Motor "A" Inverter Performance |
| P0A79-672, 690, 691, 697, 698, 701, 703 | Drive Motor "B" Inverter Performance |
| P0A7A-309, 321, 323, 342, 343, 520, 522 | Generator Inverter Performance |
| P0A94-545, 546, 551, 552, 558, 559, 561, 585, 587, 588, 589, 590 | DC / DC Converter Performance |
| P0AA6 (all INF codes) *1 | Hybrid Battery Voltage System Isolation Fault |
| P3004-132 | Power Cable Malfunction |
| P3232-749 | Open or Short to B+ in Blocking of HV Gate Connection |
| P3233-750 | Short to B+ in Blocking of HV Gate Connection |
|
| ||||
| A | |
| 2.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR) |
Turn the power switch off.
Remove the service plug grip (Click here).
![]() |
Remove the inverter cover (Click here).
Check the connections of the MG ECU connectors.
|
| ||||
| OK | |
| 3.CHECK INVERTER WITH CONVERTER ASSEMBLY (MG2) |
Check that the service plug grip is not installed.
![]() |
Check that the bolts for the three-phase AC cables are tightened to the specified torque, the three-phase AC cables are connected securely, and there are no contact problems.
Check for arc marks at the bolts for the motor cable.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
|
| ||||
|
| ||||
| A | |
| 4.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2) |
Check that the service plug grip is not installed.
![]() |
Disconnect the three-phase AC cable for MG2 from the inverter with converter assembly.
![]() |
Using a milliohmmeter, measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| U - V | Power switch off (68°F (20°C)) | 52.4 to 58.4 mΩ |
| V - W | Power switch off (68°F (20°C)) | 50.5 to 56.5 mΩ |
| W - U | Power switch off (68°F (20°C)) | 50.5 to 56.5 mΩ |
To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 68°F (20°C).
Calculate the difference between the maximum and minimum resistance.
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| MG2 U terminal - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| MG2 V terminal - Body ground and shield ground | Power switch off | 100 MΩ or higher |
| MG2 W terminal - Body ground and shield ground | Power switch off | 100 MΩ or higher |
|
| ||||
| OK | ||
| ||