DTC    P0A78-506    Drive Motor "A" Inverter Performance

for Preparation Click here


DESCRIPTION

Refer to the description of the inverter .
If the motor inverter overheats, has a circuit malfunction, or has an internal short, the inverter will transmit this information to the MFIV terminal of the MG ECU via the motor inverter fail signal line.

HINT:
The term "drive motor A" indicates MG2.


DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A78
506
Motor inverter overcurrent signal is detected (overcurrent by hybrid vehicle transaxle assembly malfunction)
  1. Wire harness or connector
  2. Hybrid vehicle transaxle assembly
  3. Inverter with converter assembly (MG ECU)

MONITOR DESCRIPTION

If excessive amperage flows through the motor inverter due to an internal short, the motor inverter will transmit an inverter fail signal to the MG ECU. Upon receiving this signal, the hybrid vehicle control ECU will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A78 (INF 506): Motor inverter / MFIV detection (load short circuit)
Required sensors / components
Motor inverter
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the DTCs listed are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


Motor inverter
Overcurrent (internal short)

COMPONENT OPERATING RANGE


Motor inverter
DTC P0A78 (INF 506) is not detected

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals. After waiting for 5 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

HINT:
Waiting for at least 5 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

1.CHECK DTC OUTPUT (HV)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A78-506 only is output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A1A (all INF codes) *1
    Generator Control Module
    P0A1B (all INF codes) *1
    Drive Motor "A" Control Module
    P0A1C (all INF codes) *1
    Drive Motor "B" Control Module
    P0A1D (all INF codes) *1
    Hybrid Powertrain Control Module
    P0A2B-248, 250
    Drive Motor "A" Temperature Sensor Circuit Range / Performance
    P0A2C-247
    Drive Motor "A" Temperature Sensor Circuit Low
    P0A2D-249
    Drive Motor "A" Temperature Sensor Circuit High
    P0A37-258, 260
    Generator Temperature Sensor Circuit Range / Performance
    P0A38-257
    Generator Temperature Sensor Circuit Low
    P0A39-259
    Generator Temperature Sensor Circuit High
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range / Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A45-669
    Drive Motor "B" Position Sensor Circuit
    P0A46-671
    Drive Motor "B" Position Sensor Circuit Range / Performance
    P0A47-670
    Drive Motor "B" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range / Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A55-687
    Drive Motor "B" Current Sensor Circuit
    P0A60 (all INF codes) *1
    Drive Motor "A" Phase V Current
    P0A63 (all INF codes) *1
    Drive Motor "A" Phase W Current
    P0A69 (all INF codes) *1
    Drive Motor "B" Phase V Current
    P0A6C (all INF codes) *1
    Drive Motor "B" Phase W Current
    P0A72 (all INF codes) *1
    Generator Phase V Current
    P0A75 (all INF codes) *1
    Generator Phase W Current
    P0A78-266, 267, 272, 278, 279, 280, 282, 283, 284, 285, 286, 287, 304, 305, 306, 503, 504, 505, 508, 510, 523, 586
    Drive Motor "A" Inverter Performance
    P0A79 (all INF codes) *1
    Drive Motor "B" Inverter Performance
    P0A7A (all INF codes) *1
    Generator Inverter Performance
    P0A90-251, 509
    Drive Motor "A" Performance
    P0A92-261, 521
    Hybrid Generator Performance
    P0A94-442, 545, 546, 547, 548, 549, 550, 551, 552, 553, 556, 557, 558, 559, 561, 585, 587, 588, 589, 590
    DC / DC Converter Performance
    P0AA6 (all INF codes) *1
    Hybrid Battery Voltage System Isolation Fault
    P0ADB-227
    Hybrid Battery Positive Contactor Control Circuit Low
    P0ADC-226
    Hybrid Battery Positive Contactor Control Circuit High
    P0ADF-229
    Hybrid Battery Negative Contactor Control Circuit Low
    P0AE0-228
    Hybrid Battery Negative Contactor Control Circuit High
    P0AE6-225
    Hybrid Battery Positive Contactor Circuit Stuck Open
    P0AE7-224
    Hybrid Battery Precharge Contactor Control Circuit High
    P3004 (all INF codes) *1
    Power Cable Malfunction
    P3226-562, 563
    Power Cable Malfunction

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic flowchart.
    2. Turning the power switch on (IG) with the service plug grip and inverter cover removed causes interlock switch system DTC P0A0D-350 to be output.
    3. P0A78-506 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.



B
GO TO DTC CHART (Click here)
A


2.CHECK CONNECTOR CONNECTION CONDITION (HYBRID VEHICLE CONTROL ECU CONNECTOR)


    A174883E01
  1. Check the connections of the hybrid vehicle control ECU connectors.

    OK:
    The connectors are connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


3.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the power switch off.

  1. Remove the service plug grip (Click here).

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the inverter cover (Click here).

    NOTICE:
    1. Wrap the round interlock terminal for the inverter cover with insulating tape to prevent it from shorting to ground.
    2. Be sure to prevent coolant in the inverter reserve tank from entering the inverter.
    3. Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.



    A170989E01
  1. Check the connections of the MG ECU connectors.

    OK:
    The connectors are connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


4.CHECK INVERTER WITH CONVERTER ASSEMBLY (MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.



    A105180
  1. Check that the bolts for the three-phase AC are tightened to the specified torque, the three-phase AC is connected securely, and there are no contact problems.

    Specified Condition:
    T=10 N*m {102 kgf*cm, 7 ft.*lbf}

    NOTICE:
    1. Be sure to use a torque wrench to tighten the bolts.
    2. Make sure that the tightening torque is between 8.0 and 12 N*m {82 to 122 kgf*cm, 6 to 9 ft.*lbf}.

  1. Check for arc marks at the bolts for the motor cable.

Result:
Result
Proceed to
The terminals are connected securely and there are no contact problems.
There are no arc marks.
A
The terminals are not connected securely and there is a contact problem.
There are arc marks.
B
The terminals are not connected securely and there is a contact problem.
There are no arc marks.
C
The terminals are connected securely and there are no contact problems.
There are arc marks.
B



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


5.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG2)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.



    A174452E03
  1. Disconnect the three-phase AC cable for MG2 from the inverter with converter assembly.



    A111755E05
  1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    U - V
    Power switch off
    (68°F (20°C))
    52.4 to 58.4 mΩ or less
    V - W
    Power switch off
    (68°F (20°C))
    50.5 to 56.5 mΩ or less
    W - U
    Power switch off
    (68°F (20°C))
    50.5 to 56.5 mΩ or less

    NOTICE:
    If the MG2 temperature is high, the resistance will vary greatly from specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

  1. To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 68°F (20°C).

    HINT:
    1. R20 = Rt / {1 + 0.00393 X (T - 20)}
    2. R20: Resistance at 68°F (20°C) (mΩ)
    3. Rt: Measured resistance (mΩ)
    4. T: Temperature when the resistance is measured (°C)

  1. Calculate the difference between the maximum and minimum resistance.

    Standard resistance:
    Difference is 5 mΩ or less

  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    MG2 U terminal - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    MG2 V terminal - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    MG2 W terminal - Body ground and shield ground
    Power switch off
    100 MΩ or higher



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK


6.CHECK HARNESS AND CONNECTOR (MG ECU - MOTOR RESOLVER)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.



    A174438E07
  1. Disconnect the B49 connector from the MG ECU.

  1. Turn the power switch on (IG).

  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-13 (MRF) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-23 (MRFG) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-21 (MSN) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-20 (MSNG) - Body ground
    Power switch on (IG)
    Below 1V
    B49-19 (MCS) - Body ground
    Power switch on (IG)
    Below 1 V
    B49-18 (MCSG) - Body ground
    Power switch on (IG)
    Below 1 V

    NOTICE:
    Turning the power switch on (IG) with the MG ECU connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing the inspection.

  1. Turn the power switch off.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-13 (MRF) - B49-23 (MRFG)
    Power switch off
    7.65 to 10.2 Ω
    B49-21 (MSN) - B49-20 (MSNG)
    Power switch off
    12.6 to 16.8 Ω
    B49-19 (MCS) - B49-18 (MCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B49-13 (MRF) or B49-23 (MRFG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    B49-21 (MSN) or B49-20 (MSNG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    B49-19 (MCS) or B49-18 (MCSG) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
Go to step 8
OK


7.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A174890
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)  

8.CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    A174890
  1. Check the connection of the motor resolver connector.

    OK:
    The connector is connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


9.CHECK MOTOR RESOLVER
  1. Disconnect the B54 motor resolver connector.



    A174440E10
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B54-1 (MRF) - B54-4 (MRFG)
    Power switch off
    7.65 to 10.2 Ω
    B54-2 (MSN) - B54-5 (MSNG)
    Power switch off
    12.6 to 16.8 Ω
    B54-3 (MCS) - B54-6 (MCSG)
    Power switch off
    12.6 to 16.8 Ω

  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    B54-1 (MRF) - B54-2 (MSN)
    Power switch off
    10 MΩ or higher
    B54-1 (MRF) - B54-3 (MCS)
    Power switch off
    10 MΩ or higher
    B54-2 (MSN) - B54-3 (MCS)
    Power switch off
    10 MΩ or higher
    B54-4 (MRFG) - B54-5 (MSNG)
    Power switch off
    10 MΩ or higher
    B54-4 (MRFG) - B54-6 (MCSG)
    Power switch off
    10 MΩ or higher
    B54-5 (MSNG) - B54-6 (MCSG)
    Power switch off
    10 MΩ or higher
    Each terminal listed above - Transaxle housing
    Power switch off
    10 MΩ or higher



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK

REPAIR OR REPLACE HARNESS OR CONNECTOR