DTC    P0A7A-344    Generator Inverter Performance

for Preparation Click here


DESCRIPTION

Refer to the description of the inverter .
If the MG1 torque execution value does not correspond to the torque command value from the MG ECU to MG1, the hybrid vehicle control ECU will store this DTC.

DTC No.
INF Code
DTC Detection Condition
Trouble Area
PA7A
344
Malfunction in monitoring MG1 torque performance
  1. Hybrid vehicle transaxle assembly
  2. Inverter with converter assembly (MG ECU)

MONITOR DESCRIPTION

If the difference between the requested MG1 torque and the actual MG1 torque exceeds a predetermined value, the MG ECU determines that there is a malfunction in the execution or monitoring of the MG1 torque. Then, the hybrid vehicle control ECU will illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A7A (INF 344): Discrepancy between monitored torque and commanded torque of MG1
Required sensors / components
Generator inverter
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the DTCs listed are not present
TMC's intellectual property

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


Generator inverter
DTC P0A7A (INF 344) is not detected

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals. After waiting for 5 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

HINT:
Waiting for at least 5 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

1.CHECK DTC OUTPUT (HV)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A7A-344 only is output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A1A (all INF codes) *1
    Generator Control Module
    P0A1B (all INF codes) *1
    Drive Motor "A" Control Module
    P0A1C (all INF codes) *1
    Drive Motor "B" Control Module
    P0A1D (all INF codes) *1
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range / Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A45-669
    Drive Motor "B" Position Sensor Circuit
    P0A46-671
    Drive Motor "B" Position Sensor Circuit Range / Performance
    P0A47-670
    Drive Motor "B" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range / Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A51-174
    Drive Motor "A" Current Sensor Circuit
    P0A55-687
    Drive Motor "B" Current Sensor Circuit
    P0A60 (all INF codes) *1
    Drive Motor "A" Phase V Current
    P0A63 (all INF codes) *1
    Drive Motor "A" Phase W Current
    P0A69 (all INF codes) *1
    Drive Motor "B" Phase V Current
    P0A6C (all INF codes) *1
    Drive Motor "B" Phase W Current
    P0A72 (all INF codes) *1
    Generator Phase V Current
    P0A75 (all INF codes) *1
    Generator Phase W Current
    P0A78-266, 267, 272, 278, 280, 283, 285, 304, 305, 306, 508, 510, 523, 586
    Drive Motor "A" Inverter Performance
    P0A79-672, 690, 691, 697, 698, 701, 703
    Drive Motor "B" Inverter Performance
    P0A7A-309, 321, 323, 342, 343, 520, 522
    Generator Inverter Performance
    P0A94-545, 546, 551, 552, 558, 559, 561, 585, 587, 588, 589, 590
    DC / DC Converter Performance
    P0AA6 (all INF codes) *1
    Hybrid Battery Voltage System Isolation Fault
    P3004-132
    Power Cable Malfunction
    P3232-749
    Open or Short to B+ in Blocking of HV Gate Connection
    P3233-750
    Short to B+ in Blocking of HV Gate Connection

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic flowchart.
    2. Turning the power switch on (IG) with the service plug grip and inverter cover removed causes interlock switch system DTC P0A0D-350 to be output.
    3. P0A7A-344 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.



B
GO TO DTC CHART (Click here)
A


2.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the power switch off.

  1. Remove the service plug grip (Click here).

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

  1. Remove the inverter cover (Click here).

    NOTICE:
    1. Wrap the round interlock terminal for the inverter cover with insulating tape to prevent it from shorting to ground.
    2. Be sure to prevent coolant in the inverter reserve tank from entering the inverter.
    3. Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.



    A170989E01
  1. Check the connections of the MG ECU connectors.

    OK:
    The connectors are connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


3.CHECK INVERTER WITH CONVERTER ASSEMBLY (MG1)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.



    A105181
  1. Check that the bolts for the three-phase AC cable for MG1 are tightened to the specified torque, the three-phase AC cable for MG1 is connected securely, and there are no contact problems.

    Specified Condition:
    T=10 N*m {102 kgf*cm, 7 ft.*lbf}

    NOTICE:
    1. Be sure to use a torque wrench to tighten the bolts.
    2. Make sure that the tightening torque is between 8.0 and 12 N*m {82 to 122 kgf*cm, 6 to 9 ft.*lbf}.

  1. Check for arc marks at the bolts for the MG1 cable.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


4.INSPECT HYBRID VEHICLE TRANSAXLE ASSEMBLY (MG1)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.



  1. Disconnect the three-phase AC cables for MG2 and MG1 from the inverter with converter assembly.


    A174429E03



    A111753E04
  1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Condition
    Specified Condition
    U - V
    Power switch off
    (68°F (20°C))
    37 to 41 mΩ
    V - W
    Power switch off
    (68°F (20°C))
    36 to 40 mΩ
    W - U
    Power switch off
    (68°F (20°C))
    36 to 40 mΩ

    NOTICE:
    If the MG1 temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

  1. To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 68°F (20°C).

    HINT:
    1. R20 = Rt / {1 + 0.00393 X (T - 20)}
    2. R20: Resistance at 68°F (20°C) (mΩ)
    3. Rt: Measured resistance (mΩ)
    4. T: Temperature when the resistance is measured (°C)

  1. Calculate the difference between the maximum and minimum resistance.

    Standard resistance:
    Difference is 3 mΩ or less

  1. Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    U - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    V - Body ground and shield ground
    Power switch off
    100 MΩ or higher
    W - Body ground and shield ground
    Power switch off
    100 MΩ or higher



NG
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY (Click here)
OK

REPLACE INVERTER WITH CONVERTER ASSEMBLY (Click here)