DTC P0A90-251 Drive Motor "A" Performance |

| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P0A90 | 251 | Motor magnetic force deterioration or same phase short circuit |
|
| Related DTCs | P0A90 (INF 251): Magnetic force deterioration / same phase short circuit |
| Required sensors / components | Hybrid vehicle motor, inverter, motor resolver |
| Frequency of operation | Continuous |
| Duration | TMC's intellectual property |
| MIL operation | Immediately |
| Sequence of operation | None |
| The monitor will run whenever the following DTCs are not present | TMC's intellectual property |
| Other conditions belong to TMC's intellectual property | - |
| TMC's intellectual property | - |
| MG ECU | DTC P0A90 (INF 251) is not detected |
| 1.CHECK DTC OUTPUT (HV) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A90-251 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A1A (all INF codes) *1 | Generator Control Module |
| P0A1B (all INF codes) *1 | Drive Motor "A" Control Module |
| P0A1C (all INF codes) *1 | Drive Motor "B" Control Module |
| P0A1D (all INF codes) *1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range / Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A45-669 | Drive Motor "B" Position Sensor Circuit |
| P0A46-671 | Drive Motor "B" Position Sensor Circuit Range / Performance |
| P0A47-670 | Drive Motor "B" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range / Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A51-174 | Drive Motor "A" Current Sensor Circuit |
| P0A55-687 | Drive Motor "B" Current Sensor Circuit |
| P0A60 (all INF codes) *1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes) *1 | Drive Motor "A" Phase W Current |
| P0A69 (all INF codes) *1 | Drive Motor "B" Phase V Current |
| P0A6C (all INF codes) *1 | Drive Motor "B" Phase W Current |
| P0A72 (all INF codes) *1 | Generator Phase V Current |
| P0A75 (all INF codes) *1 | Generator Phase W Current |
| P0A78-266, 267, 272, 278, 280, 283, 285, 287, 304, 305, 306, 505, 508, 510, 523, 586 | Drive Motor "A" Inverter Performance |
| P0A79-672, 690, 691, 697, 698, 701, 703 | Drive Motor "B" Inverter Performance |
| P0A7A-309, 321, 323, 342, 343, 520, 522 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A91-702 | Drive Motor "B" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0A94-545, 546, 551, 552, 558, 559, 561, 585, 587, 588, 589, 590 | DC / DC Converter Performance |
| P0AA6 (all INF codes) *1 | Hybrid Battery Voltage System Isolation Fault |
| P3004-132 | Power Cable Malfunction |
| P3232-749 | Open or Short to B+ in Blocking of HV Gate Connection |
| P3233-750 | Short to B+ in Blocking of HV Gate Connection |
|
| ||||
| A | |
| 2.REPRODUCTION TEST |
Connect the Techstream to the DLC3.
Test-drive the vehicle at a speed of 25 mph (40 km/h) for approximately 1 minute.
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | Proceed to |
| P0A90-251 is output or no DTC is output | A |
| P0A78-306 or P0A90-509 is output | B |
|
| ||||
| A | |
| 3.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR) |
Turn the power switch off.
Remove the service plug grip (Click here).
Remove the inverter cover (Click here).
![]() |
Check the connections of the MG ECU connectors.
|
| ||||
| OK | |
| 4.CHECK INVERTER WITH CONVERTER ASSEMBLY (MG2) |
Check that the service plug grip is not installed.
![]() |
Check that the bolts for the three-phase AC cable for MG2 are tightened to the specified torque, the three-phase AC cable for MG2 is connected securely, and there are no contact problems.
Check for arc marks at the bolts for the motor cable.
| Result | Proceed to | |
| The terminals are connected securely and there are no contact problems. | There are no arc marks. | A |
| The terminals are not connected securely and there is a contact problem. | There are arc marks. | B |
| The terminals are not connected securely and there is a contact problem. | There are no arc marks. | C |
| The terminals are connected securely and there are no contact problems. | There are arc marks. | B |
|
| ||||
|
| ||||
| A | ||
| ||