Home › HYBRID SYSTEM · P310 › HYBRID VEHICLE CONTROL › HYBRID CONTROL SYSTEM

DTC    P0A91-705    Drive Motor "B" Performance

for Preparation Click here


DESCRIPTION

Refer to the description of MGR .

HINT:
The term "drive motor B" indicates MGR.


DTC No.
INF Code
DTC Detection Condition
Trouble Area
P0A91
705
Rear motor magnetic force deterioration or same phase short circuit
  1. Rear traction motor with transaxle assembly
  2. No. 3 frame wire
  3. Extension wire assembly
  4. Inverter with converter assembly (MG ECU)

MONITOR DESCRIPTION

The MG ECU monitors MGR. If the MG ECU detects a reduction in the magnetic force of MGR or an in-phase short, it interprets this as a MGR failure. The hybrid vehicle control ECU wil illuminate the MIL and set a DTC.

MONITOR STRATEGY


Related DTCs
P0A91 (INF 705): Magnetic force deterioration / Same phase short circuit
Required sensors / components
Hybrid vehicle rear motor, inverter, rear motor resolver
Frequency of operation
Continuous
Duration
TMC's intellectual property
MIL operation
Immediately
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the DTCs listed are not present
TMC's intellectual property
Other conditions belong to TMC's intellectual property
-

TYPICAL MALFUNCTION THRESHOLDS


TMC's intellectual property
-

COMPONENT OPERATING RANGE


Hybrid vehicle rear motor
DTC P0A91 (INF 705) is not detected

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals. After waiting for 5 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work.

HINT:
Waiting for at least 5 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

1.CHECK DTC OUTPUT (HV)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A91-705 only is output.
    A
    Any of the following DTCs are also output.
    B


    DTC No.
    Relevant Diagnosis
    P0A1A (all INF codes) *1
    Generator Control Module
    P0A1B (all INF codes) *1
    Drive Motor "A" Control Module
    P0A1C (all INF codes) *1
    Drive Motor "B" Control Module
    P0A1D (all INF codes) *1
    Hybrid Powertrain Control Module
    P0A3F-243
    Drive Motor "A" Position Sensor Circuit
    P0A40-500
    Drive Motor "A" Position Sensor Circuit Range / Performance
    P0A41-245
    Drive Motor "A" Position Sensor Circuit Low
    P0A45-669
    Drive Motor "B" Position Sensor Circuit
    P0A46-671
    Drive Motor "B" Position Sensor Circuit Range / Performance
    P0A47-670
    Drive Motor "B" Position Sensor Circuit Low
    P0A4B-253
    Generator Position Sensor Circuit
    P0A4C-513
    Generator Position Sensor Circuit Range / Performance
    P0A4D-255
    Generator Position Sensor Circuit Low
    P0A51-174
    Drive Motor "A" Current Sensor Circuit
    P0A55-687
    Drive Motor "B" Current Sensor Circuit
    P0A60 (all INF codes) *1
    Drive Motor "A" Phase V Current
    P0A63 (all INF codes) *1
    Drive Motor "A" Phase W Current
    P0A69 (all INF codes) *1
    Drive Motor "B" Phase V Current
    P0A6C (all INF codes) *1
    Drive Motor "B" Phase W Current
    P0A72 (all INF codes) *1
    Generator Phase V Current
    P0A75 (all INF codes) *1
    Generator Phase W Current
    P0A78-266, 267, 272, 278, 280, 283, 285, 304, 305, 306, 508, 510, 523, 586
    Drive Motor "A" Inverter Performance
    P0A79-672, 690, 691, 693, 694, 697, 698, 701, 703
    Drive Motor "B" Inverter Performance
    P0A7A-309, 321, 323, 342, 343, 520, 522
    Generator Inverter Performance
    P0A90-509
    Drive Motor "A" Performance
    P0A91-702
    Drive Motor "B" Performance
    P0A92-521
    Hybrid Generator Performance
    P0A94-545, 546, 551, 552, 558, 559, 561, 585, 587, 588, 589, 590
    DC / DC Converter Performance
    P0AA6 (all INF codes) *1
    Hybrid Battery Voltage System Isolation Fault
    P3004-132
    Power Cable Malfunction
    P3232-749
    Open or Short to B+ in Blocking of HV Gate Connection
    P3233-750
    Short to B+ in Blocking of HV Gate Connection

    HINT:
    1. *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic flowchart.
    2. Turning the power switch on (IG) with the service plug grip and inverter cover removed causes interlock switch system DTC P0A0D-350 to be output.
    3. P0A91-705 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.



B
GO TO DTC CHART (Click here)
A


2.REPRODUCTION TEST
  1. Connect the Techstream to the DLC3.

  1. Test-drive the vehicle at a speed of 25 mph (40 km/h) for approximately 1 minute.

  1. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

  1. Check if DTCs are output.

    Result:
    Result
    Proceed to
    P0A91-705 is output or no DTC is output
    A
    P0A79-704 or P0A91-702 is output
    B



B
GO TO DTC CHART (Click here)
A


3.CHECK REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY

CAUTION:
Be sure to wear insulated gloves.

  1. Turn the power switch off.

  1. Remove the service plug grip (Click here).

    NOTICE:
    After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.



    A105187
  1. Check that the nuts for the three-phase AC cable are tightened to the specified torque, and it is connected securely, and there are no contact problems.

    Specified Condition:
    T=15 N*m {153 kgf*cm, 11 ft.*lbf}

  1. Check for arc marks at the terminals for the three-phase AC cable for MGR the rear traction motor with transaxle assembly.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


4.CHECK CONNECTOR CONNECTION CONDITION (MG ECU CONNECTOR)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is removed.

  1. Remove the inverter cover (Click here).

    NOTICE:
    1. Wrap the round interlock terminal for the inverter cover with insulating tape to prevent it from shorting to ground.
    2. Be sure to prevent coolant in the inverter reserve tank from entering the inverter.
    3. Removing the inverter cover causes the MG ECU board to be exposed. Therefore, temporarily install the inverter cover for each area to be inspected.



    A170989E01
  1. Check the connections of the MG ECU connectors.

    OK:
    The connectors are connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


5.CHECK INVERTER WITH CONVERTER ASSEMBLY (MGR)

CAUTION:
Be sure to wear insulated gloves.

  1. Check that the service plug grip is not installed.



    A174239E06
  1. Check that the bolts for the three-phase AC cable for MGR are tightened to the specified torque, the three-phase AC cable for MGR is connected securely, and there are no contact problems.

    Specified Condition:
    T=10 N*m {102 kgf*cm, 7 ft.*lbf}

    NOTICE:
    1. Be sure to use a torque wrench to tighten the bolts.
    2. Make sure that the tightening torque is between 8.0 and 12 N*m {82 to 122 kgf*cm, 6 to 9 ft.*lbf}.

  1. Check for arc marks at the bolts for the cable.

    Result:
    Result
    Proceed to
    The terminals are connected securely and there are no contact problems.
    There are no arc marks.
    A
    The terminals are not connected securely and there is a contact problem.
    There are arc marks.
    B
    The terminals are not connected securely and there is a contact problem.
    There are no arc marks.
    C
    The terminals are connected securely and there are no contact problems.
    There are arc marks.
    B



B
REPLACE MALFUNCTIONING PARTS

C
CONNECT SECURELY
A


6.CHECK NO. 3 FRAME WIRE

CAUTION:
Be sure to wear insulated gloves.



    A174239E06
  1. Turn the power switch off and remove the service plug grip.

    NOTICE:
    Do not turn the power switch on (READY) with the service plug grip removed as this may cause a malfunction.

  1. Disconnect the three-phase AC cable for MGR from the rear traction motor with transaxle assembly.



    A174905E06
  1. Disconnect the three-phase AC cable for MGR from the inverter with converter assembly.

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    U - U
    Power switch off
    Below 1 Ω
    V - V
    Power switch off
    Below 1 Ω
    W - W
    Power switch off
    Below 1 Ω



NG
REPLACE NO. 3 FRAME WIRE
OK


7.INSPECT EXTENSION WIRE ASSEMBLY
  1. Remove the rear traction motor with transaxle assembly (Click here).

  1. Remove the extension wire assembly from the rear traction motor with transaxle assembly.



    A174455E01
  1. Using a megohmmeter, measure the insulation resistance according to the value(s) in the table below.

    NOTICE:
    Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    U - Shield shell
    Power switch off
    10 MΩ or higher
    V - Shield shell
    Power switch off
    10 MΩ or higher
    W - Shield shell
    Power switch off
    10 MΩ or higher

  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Specified Condition
    U - U
    Power switch off
    Below 1 Ω
    V - V
    Power switch off
    Below 1 Ω
    W - W
    Power switch off
    Below 1 Ω



NG
REPLACE EXTENSION WIRE ASSEMBLY
OK

REPLACE REAR TRACTION MOTOR WITH TRANSAXLE ASSEMBLY (Click here)