DTC P3004-800 Power Cable Malfunction |
DTC P3004-801 Power Cable Malfunction |
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
| P3004 | 800 | Excessive overcurrent occurs during precharge (time from when SMR1 turns on until when SMR2 turns on) |
|
| 801 | Minimal overcurrent occurs during precharge (time from when SMR1 turns on until when SMR2 turns on) |
| 1.CHECK DTC OUTPUT (HV) |
Connect the Techstream to the DLC3.
Turn the power switch on (IG).
Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.
| Result | Proceed to |
| P3004-800 or P3004-801 only is output. | A |
| Any of the following DTCs are also output. | B |
| DTC No. | Relevant Diagnosis |
| P0A09 (all INF codes) *1 | DC / DC Converter Status Circuit Low Input |
| P0A10 (all INF codes) *1 | DC / DC Converter Status Circuit High Input |
|
| ||||
| A | |
| 2.CHECK WIRE HARNESS AND CONNECTOR (HYBRID VEHICLE CONTROL ECU - MG ECU) |
Turn the power switch off.
Remove the service plug grip (Click here).
Disconnect the A43 connector from the hybrid vehicle control ECU.
Remove the inverter cover (Click here).
Disconnect the A42 connector from the MG ECU.
![]() |
Measure the voltage according to the value(s) in the table below when the power switch is on (IG).
| Tester Connection | Switch Condition | Specified Condition |
| A43-11 (NODD) - Body ground | Power switch on (IG) | Below 1 V |
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| A43-11 (NODD) - A42-33 (NODD) | Power switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
| A43-11 (NODD) or A42-33 (NODD) - Body ground and other terminals | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | |
| 3.CHECK WITH MOTOR COMPRESSOR ASSEMBLY |
Check that the service plug grip is not installed.
![]() |
Disconnect the No. 4 engine wire from the air conditioning wiring harness.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 (+) - 2 (-) | Power switch off | 100 Ω or higher |
|
| ||||
| OK | |
| 4.CHECK NO. 3 FRAME WIRE |
![]() |
Disconnect the No. 3 frame wire (DC cable for the HV battery) from the inverter with converter assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 (+) - 2 (-) | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 5.CHECK NO. 3 FRAME WIRE (INVERTER WITH CONVERTER ASSEMBLY - HV RELAY ASSEMBLY) |
![]() |
Disconnect the No. 3 frame wire (DC cable for the inverter with converter assembly) from the HV relay assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| j2-1 - j3-1 | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||
| 6.CHECK NO. 4 ENGINE WIRE |
![]() |
Disconnect the No. 4 engine wire from the with motor compressor assembly.
![]() |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| 1 - 2 | Power switch off | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||