DTC B1794 Open in Occupant Classification ECU Battery Positive Line |
| DTC No. | DTC Detection Condition | Trouble Area |
| B1794 |
|
|

| 1.CHECK BATTERY |
Measure the voltage of the battery.
|
| ||||
| OK | |
| 2.CHECK FUSE |
Measure the resistance of the ECU-B fuse.
|
| ||||
| OK | |
| 3.CHECK WIRE HARNESS (SOURCE VOLTAGE) |
![]() |
Turn the power switch off.
Disconnect the negative (-) terminal cable from the battery.
Disconnect the connector from the occupant classification ECU.
Connect the negative (-) terminal cable to the battery.
Turn the power switch on (IG).
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a3-1 (+B) - Body ground | Always | 11 to 14 V |
| a3-7 (IG) - Body ground | power switch on (IG) | 11 to 14 V |
Turn the power switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| a3-3 (GND) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 4.CHECK DTC |
Turn the power switch off.
Disconnect the negative (-) terminal cable from the battery.
Connect the connector to the occupant classification ECU.
Connect Techstream to the DLC3.
Connect the negative (-) terminal cable to the battery.
Turn the power switch on (IG).
Clear the DTCs stored in the occupant classification ECU (Click here).
Clear the DTCs stored in the center airbag sensor assembly (Click here).
Turn the power switch off.
Turn the power switch on (IG), and wait for at least 10 seconds.
Using Techstream, check for DTCs of the occupant classification ECU (Click here).
|
| ||||
| OK | ||
| ||
| 5.REPLACE OCCUPANT CLASSIFICATION ECU |
Turn the power switch off.
Disconnect the negative (-) terminal cable from the battery.
Replace the occupant classification ECU (Click here).
| NEXT | |
| 6.PERFORM ZERO POINT CALIBRATION |
Connect the negative (-) terminal cable to the battery.
Connect Techstream to the DLC3.
Turn the power switch on (IG).
Using Techstream, perform the "zero point calibration" (Click here).
| NEXT | |
| 7.PERFORM SENSITIVITY CHECK |
Using Techstream, perform "sensitivity check" (Click here).
| NEXT | ||
| ||