SLIDING ROOF SYSTEM > Sliding Roof does not Move by Operating Sliding Roof Control Switch |

| 1.INSPECT FUSE (DC/DC, S/ROOF, ECU-IG NO. 1) |
Remove the DC/DC fuse from the engine room main relay block.
Remove the S/ROOF and ECU-IG No. 1 fuses from the instrument panel junction block.
Measure the resistance of the fuses.
| Tester Connection | Condition | Specified Condition |
| DC/DC fuse | Always | Below 1 Ω |
| S/ROOF fuse | Always | Below 1 Ω |
| ECU-IG No.1 fuse | Always | Below 1 Ω |
|
| ||||
| OK | |
| 2.CHECK WIRE HARNESS (SLIDING ROOF CONTROL ECU - BATTERY AND BODY GROUND) |
![]() |
Disconnect the Q12 connector.
Measure the voltage and resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
| Q12-1 (B) - Body ground | Always | 10 to 14 V |
| Q12-5 (IG) - Body ground | Power switch on (IG) | 10 to 14 V |
| Q12-5 (IG) - Body ground | Power switch off | Below 1 V |
| Tester Connection | Condition | Specified Condition |
| Q12-2 (E) - Body ground | Always | Below 1 Ω |
|
| ||||
| OK | |
| 3.PERFORM ACTIVE TEST BY TECHSTREAM (SLIDING ROOF OPERATION) |
Select the Active Test, use the Techstream to generate a control command, and then check that the sliding roof slides open/close and tilts up/down (Click here).
| Tester Display | Test Part | Control Range | Diagnostic Note |
| Slide Roof | Operate sliding roof SLIDE CLOSE/TILT UP | Clos/Up: Sliding roof SLIDE CLOSE or TILT UP operation occurs. OFF: Sliding roof is not operating. | - |
| Slide Roof | Operate sliding roof SLIDE OPEN/TILT DOWN | Opn/Dwn: Sliding roof SLIDE OPEN or TILT DOWN operation occurs. OFF: Sliding roof is not operating. | - |
|
| ||||
| OK | |
| 4.READ VALUE USING TECHSTREAM (SLIDING ROOF CONTROL ECU) |
Use the Data List to check if the sliding roof switch assembly is functioning properly (Click here).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Hall IC1 Pulse | Sliding roof operation signal/LO or HI | LO: Sliding roof motor is not operating. HI: Sliding roof motor is operating. | - |
| Hall IC1 Status | Sliding roof operation signal/NORMAL or LOCK | NORMAL: Sliding roof motor is operating. LOCK: Sliding roof motor is not operating. | - |
| Hall IC2 Pulse | Sliding roof operation signal/LO or HI | LO: Sliding roof motor is not operating. HI: Sliding roof motor is operating. | - |
| Hall IC2 Status | Sliding roof operation signal/NORMAL or LOCK | NORMAL: Sliding roof motor is operating. LOCK: Sliding roof motor is not operating. | - |
|
| ||||
| OK | |
| 5.READ VALUE USING TECHSTREAM (SLIDING ROOF SWITCH ASSEMBLY) |
Use the Data List to check if the sliding roof switch assembly is functioning properly (Click here).
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
| Open Switch | Slide switch open signal/ON or OFF | ON: OPEN switch is pressed. OFF: OPEN switch is not pressed. | - |
| Close Switch | Slide switch close signal/ON or OFF | ON: CLOSE switch is pressed. OFF: CLOSE switch is not pressed. | - |
| Up Switch | Tilt switch up signal/ON or OFF | ON: UP switch is pressed. OFF: UP switch is not pressed. | - |
| Down Switch | Tilt switch down signal/ON or OFF | ON: DOWN switch is pressed. OFF: DOWN switch is not pressed. | - |
|
| ||||
| OK | ||
| ||
| 6.INSPECT ROOF CONSOLE BOX ASSEMBLY (SLIDING ROOF SWITCH ASSEMBLY) |
![]() |
Remove the roof console box assembly.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| Q1-3 (CLS) - Q1-2 (GND) | CLOSE | Below 100 Ω |
| Q1-4 (OPN) - Q1-2 (GND) | OPEN | Below 100 Ω |
| Q1-5 (DOWN) - Q1-2 (GND) | DOWN | Below 100 Ω |
| Q1-6 (UP) - Q1-2 (GND) | UP | Below 100 Ω |
| Q1-3 (CLS) - Q1-2 (GND) | OPEN | 1 kΩ or higher |
| Q1-4 (OPN) - Q1-2 (GND) | CLOSE | 1 kΩ or higher |
| Q1-5 (DOWN) - Q1-2 (GND) | UP | 1 kΩ or higher |
| Q1-6 (UP) - Q1-2 (GND) | DOWN | 1 kΩ or higher |
|
| ||||
| OK | |
| 7.CHECK WIRE HARNESS (SLIDING ROOF CONTROL ECU - ROOF CONSOLE BOX ASSEMBLY) |
![]() |
Remove the Q12 and Q1 connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
| Q12-2 (E) - Q1-2 (GND) | Always | Below 1 Ω |
| Q12-7 (OPN) - Q1-4 (OPN) | Always | Below 1 Ω |
| Q12-8 (DWN) - Q1-5 (DOWN) | Always | Below 1 Ω |
| Q12-9 (CLS) - Q1-3 (CLS) | Always | Below 1 Ω |
| Q12-10 (UP) - Q1-6 (UP) | Always | Below 1 Ω |
| Q1-3 (CLS) - Body ground | Always | 10 kΩ or higher |
| Q1-4 (OPN) - Body ground | Always | 10 kΩ or higher |
| Q1-2 (GND) - Body ground | Always | Below 1 Ω |
| Q1-5 (DOWN) - Body ground | Always | 10 kΩ or higher |
| Q1-6 (UP) - Body ground | Always | 10 kΩ or higher |
|
| ||||
| OK | ||
| ||