Home › HYBRID SYSTEM · P310 › HYBRID BATTERY CONTROL › HYBRID BATTERY SYSTEM

DTC    P0A9D-123    Hybrid Battery Temperature Sensor "A" Circuit Low

DTC    P0A9E-123    Hybrid Battery Temperature Sensor "A" Circuit High

DTC    P0AC7-123    Hybrid Battery Temperature Sensor "B" Circuit Low

DTC    P0AC8-123    Hybrid Battery Temperature Sensor "B" Circuit High

DTC    P0ACC-123    Hybrid Battery Temperature Sensor "C" Circuit Low

DTC    P0ACD-123    Hybrid Battery Temperature Sensor "C" Circuit High

for Preparation Click here


DESCRIPTION

  1. Refer to the description for DTC P0A9C-123 .

DTC No.
DTC Detection Condition
Trouble Area
P0A9D-123
P0A9E-123
P0AC7-123
P0AC8-123
P0ACC-123
P0ACD-123
When the temperature of the battery temperature sensor is less than the standard value (open) or higher than the standard value (short) (1 trip detection).
  1. HV battery assembly
  2. Battery smart unit
  3. Battery pack wire
  4. Wire harness or connector
  5. HV relay assembly

HINT:
After confirming that a DTC is output, use the Techstream to check "Temp of BATT TB 1 to 8" in the hybrid vehicle control system ECU data list.


Temperature Displayed
Malfunction
Below -49°F (-45°C)
Open or +B short circuit
203°F (95°C) or more
GND short circuit

MONITOR DESCRIPTION

If the temperature indicated by the battery temperature sensor is lower than the standard level (open circuit), or is higher than the standard level (short circuit), the battery smart unit interprets this as a sensor malfunction. If the battery smart unit detects that HV battery temperature is out of a normal range, the hybrid vehicle control ECU illuminates the MIL and sets a DTC.

MONITOR STRATEGY


Related DTCs
P0A9D-123/ P0A9E-123/ P0AC7-123/ P0AC8-123/ P0ACC-123/ P0ACD-123
Required sensors/components
Battery temperature sensor
Frequency of operation
Continuous
Duration
TOYOTA's intellectual property
MIL operation
Immediately or 2 driving cycles
Sequence of operation
None

TYPICAL ENABLING CONDITIONS


The monitor will run whenever the DTCs listed are not present
TOYOTA's intellectual property

TYPICAL MALFUNCTION THRESHOLDS


TOYOTA's intellectual property
-

COMPONENT OPERATING RANGE


Battery temperature sensor
9 to 11 kΩ at 77°F (25°C)

WIRING DIAGRAM

  1. Refer to the wiring diagram for DTC P0A85-123 .

INSPECTION PROCEDURE

CAUTION:
  1. Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
  2. After disconnecting the service plug grip, wait for at least 5 minutes before touching any of the high-voltage connectors or terminals.

HINT:
At least 5 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

1.CHECK DTC OUTPUT (DTC P0A1F IS OUTPUT)
  1. Connect the Techstream to the DLC3.

  1. Turn the power switch on (IG).

  1. Select the following menu items: Powertrain / Hybrid Control / Trouble Codes.

  1. Read output DTCs (Click here).

    Result:
    Result
    Proceed to
    P0A1F-123 is not output.
    A
    P0A1F-123 is also output.
    B



B
GO TO DTC CHART (P0A1F-123) (Click here)
A


2.CHECK CONNECTOR CONNECTION CONDITION (BATTERY TEMPERATURE SENSOR CONNECTOR)

NOTICE:
Be sure to wear insulated gloves and protective goggles.

  1. Turn the power switch off and remove the service plug grip (Click here).

    NOTICE:
    Do not turn the power switch on (READY) with the service plug grip removed as this may cause a malfunction.

  1. Remove the battery cover (Click here).



    A173696E01
  1. Check the connections of the z33 and z34 connectors of the battery smart unit.

    Result:
    Specified Condition
    The connectors are connected securely and there are no contact problems.



    A173694E01
  1. check the connections of connectors between the battery temperature sensor (No. 0) and battery temperature sensor (No. 2).

    Result:
    Specified Condition
    The connectors are connected securely and there are no contact problems.



NG
CONNECT SECURELY
OK


3.CHECK HV BATTERY (BATTERY TEMPERATURE SENSOR)

CAUTION:
Be sure to wear insulated gloves and protective goggles.



    A173713E01
  1. Disconnect the z33 and z34 connectors from the battery smart unit (Click here).

  1. Measure the resistance according to the conditions and value(s) in the tables below.
    Tester Connection
    Thermistor No.
    z33-1 (TB0) - z33-6 (GB0)
    0
    z33-2 (TB1) - z33-7 (GB1)
    1
    z34-1 (TB2) - z34-4 (GB2)
    2
    z34-2 (TB3) - z34-5 (GB3)
    3
    z34-3 (TB4) - z34-6 (GB4)
    4
    z33-3 (TB5) - z33-8 (GB5)
    5
    z33-4 (TB6) - z33-9 (GB6)
    6
    z33-5 (TB7) - z33-10 (GB7)
    7

    Standard resistance:
    Thermistor Temperature
    Switch Condition
    Specified Condition (kΩ)
    32°F (0°C)
    Power switch off
    27.0 to 27.6
    77°F (25°C)
    Power switch off
    9.9 to 10.1
    104°F (40°C)
    Power switch off
    5.77 to 5.89

  1. Disconnect the z18 connector from the battery smart unit.



    A183992E01
  1. Measure the resistance according to the conditions and value(s) in the tables below.

    Standard resistance:
    Tester Connection
    Switch Condition
    Standard resistance
    z33-1 (TB0) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z33-2 (TB1) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z34-1 (TB2) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z34-2 (TB3) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z34-3 (TB4) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z33-3 (TB5) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z33-4 (TB6) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z33-5 (TB7) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z33-6 (GB0) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z33-7 (GB1) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z34-4 (GB2) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z34-5 (GB3) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z34-6 (GB4) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z33-8 (GB5) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z33-9 (GB6) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more
    z33-10 (GB7) - z18-1 (IGCT)
    Power switch off
    10 kΩ or more



NG
REPLACE HV BATTERY ASSEMBLY (Click here)
OK


4.INSPECT BATTERY SMART UNIT
  1. Connect the z18 battery smart unit connector.

  1. Turn the power switch on (IG).



    A173705E07
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    z18-10 (VIB) - z18-12 (GIB)
    Power switch on (IG)
    4.6 to 5.4 V

    NOTICE:
    Turning the power switch on (IG) with the service plug grip removed causes an interlock switch system DTC (P0A0D-350) to be set. Use the Techstream to clear the DTCs.

  1. Reconnect the battery smart unit connector.



NG
Go to step 5
OK

REPLACE BATTERY SMART UNIT (Click here)  

5.INSPECT BATTERY SMART UNIT
  1. Disconnect the z19 battery current sensor connector from the HV relay assembly (Click here).

  1. Turn the power switch on (IG).



    A173706E01
  1. Measure the voltage according to the value(s) in the table below.

    Standard voltage:
    Tester Connection
    Switch Condition
    Specified Condition
    z19-1 (VIB) - z19-2 (GIB)
    Power switch on (IG)
    4.6 to 5.4 V

    NOTICE:
    Turning the power switch on (IG) with the HV relay assembly (battery current sensor) connector disconnected causes DTC P0AC2-123 to set. Use the Techstream to clear the DTCs.



NG
Go to step 6
OK

REPLACE HV RELAY ASSEMBLY (Click here)  

6.CHECK BATTERY PACK WIRE (BATTERY SMART UNIT - BATTERY CURRENT SENSOR)

CAUTION:
Be sure to wear insulated gloves and protective goggles.

  1. Remove the service plug grip.

  1. Remove the battery cover.

  1. Disconnect the z18 connector from the battery smart unit.

  1. Disconnect the z19 HV relay assembly (battery current sensor) connector.



    A173703E06
  1. Measure the resistance according to the value(s) in the table below.

    Standard resistance (Check for open):
    Tester Connection
    Switch Condition
    Specified Condition
    z18-11 (IB) - z19-3 (IB)
    Power switch off
    Below 1 Ω
    z18-12 (GIB) - z19-2 (GIB)
    Power switch off
    Below 1 Ω
    z18-10 (VIB) - z19-1 (VIB)
    Power switch off
    Below 1 Ω

    Standard resistance (Check for short):
    Tester Connection
    Switch Condition
    Specified Condition
    z18-11 (IB) or z19-3 (IB) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    z18-12 (GIB) or z19-2 (GIB) - Body ground and other terminals
    Power switch off
    10 kΩ or higher
    z18-10 (VIB) or z19-1 (VIB) - Body ground and other terminals
    Power switch off
    10 kΩ or higher



NG
REPLACE BATTERY PACK WIRE (Click here)
OK

REPLACE BATTERY SMART UNIT (Click here)